MoNA MS database records for Costunolide
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
NA002319 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10% (nominal) | [M+H]+ | positive | MS2 |
NA002320 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15% (nominal) | [M+H]+ | positive | MS2 |
NA002321 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20% (nominal) | [M+H]+ | positive | MS2 |
NA002322 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25% (nominal) | [M+H]+ | positive | MS2 |
NA002323 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30% (nominal) | [M+H]+ | positive | MS2 |
NA002714 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35% (nominal) | [M+H]+ | positive | MS2 |
NA002715 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40% (nominal) | [M+H]+ | positive | MS2 |
NA002716 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45% (nominal) | [M+H]+ | positive | MS2 |
NA002717 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50% (nominal) | [M+H]+ | positive | MS2 |
NA002718 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55% (nominal) | [M+H]+ | positive | MS2 |
NA003094 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60% (nominal) | [M+H]+ | positive | MS2 |
NA003095 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65% (nominal) | [M+H]+ | positive | MS2 |
NA003096 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70% (nominal) | [M+H]+ | positive | MS2 |
NA003097 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75% (nominal) | [M+H]+ | positive | MS2 |
NA003098 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80% (nominal) | [M+H]+ | positive | MS2 |
NA003459 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85% (nominal) | [M+H]+ | positive | MS2 |
NA003460 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90% (nominal) | [M+H]+ | positive | MS2 |
NA003461 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 95% (nominal) | [M+H]+ | positive | MS2 |
NA003462 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100% (nominal) | [M+H]+ | positive | MS2 |
NA003463 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105% (nominal) | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000033 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000034 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-QEHF000103 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000104 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000105 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000106 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000107 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000108 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002207 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002208 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002209 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003488 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003489 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003490 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007171 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007172 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007173 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |