MoNA MS database records for Creatine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
FiehnLib000123 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000124 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
KNA00149 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00392 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00772 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
CCMSLIB00000577904 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578136 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005463966 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463967 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005464027 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720348 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720638 | qTof | - | - | - | [M-H]- | negative | MS2 |
EMBL-MCF_spec26240 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec98208 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
FiehnHILIC000282 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
KNA00151 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00152 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M+H]+ | positive | MS2 |
KNA00393 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00394 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
KNA00395 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M+H]+ | positive | MS2 |
KNA00559 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00560 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M-H]- | negative | MS2 |
KNA00561 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [3M-H]- | negative | MS2 |
KNA00773 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00774 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M-H]- | negative | MS2 |
KNA00775 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [3M-H]- | negative | MS2 |
KO002517 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002518 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002519 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002520 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002521 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
MoNA002259 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA002260 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA002261 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA010567 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010568 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010569 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010570 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010571 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010572 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA024336 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
MoNA024339 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA032572 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032574 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032575 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA034701 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034704 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034705 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA036404 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036408 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036409 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036477 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036478 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036479 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA037048 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037360 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038111 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038483 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038692 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MT000092 | LTQ XL, Thermo Finnigan | LC-ESI-IT | ESI | 40 | [M+H]+ | positive | MS2 |
PR100111 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100534 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PS018401 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS018402 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS018403 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS018404 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS018405 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS018406 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PT101840 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT201840 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
BAF_UVA_POS000384 | Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS001301 | Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS001302 | Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS001303 | Q-Tof Premier, Waters | - | - | - | - | - | - |
HMDB0000064_c_ms_99530 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0000064_c_ms_99531 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0000064_ei_ms_1033 | Leco Pegasus IV | - | - | - | - | - | - |
HMDB0000064_ms_ms_105 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0000064_ms_ms_106 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0000064_ms_ms_107 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
MoNA010996 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA010997 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA010998 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA010999 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA016679 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |