MoNA MS database records for Cytosine
| Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|---|
| ML003201 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
| KNA00019 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M+H]+ | positive | MS2 |
| KNA00434 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M+H]+ | positive | MS2 |
| KNA00018 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
| KNA00432 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
| KNA00017 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
| KNA00431 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
| KNA00020 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
| KNA00433 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
| MoNA024363 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
| PS019301 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
| PS019302 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
| PS019303 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
| MoNA011017 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
| MoNA011018 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
| MoNA011019 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
| MoNA011020 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
| MoNA010676 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| MoNA010679 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| MoNA010677 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| MoNA010680 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| MoNA010675 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| MoNA010678 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| MoNA034064 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
| MoNA034065 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
| MoNA034067 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
| MoNA032110 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA036041 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA032108 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA036047 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA032111 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA036046 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA001920 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA001921 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
| MoNA001922 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
| KO000416 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
| KO000417 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
| KO000418 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
| KO000419 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
| KO000420 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
| FiehnLib000492 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| FiehnLib000493 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| CCMSLIB00005463926 | Orbitrap | - | - | - | [2M+H]+ | positive | MS2 |
| CCMSLIB00005463924 | Orbitrap | - | - | - | [2M+Na]+ | positive | MS2 |
| CCMSLIB00005463923 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00005463925 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
| OUF00148 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| CCMSLIB00000578106 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
| CCMSLIB00005720609 | qTof | - | - | - | [M+H]+ | positive | MS2 |
| FiehnHILIC001865 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
| FiehnHILIC001139 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA037885 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| FiehnHILIC000295 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA037168 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA038560 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec22955 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 28.33 eV | [M-H]- | negative | MS2 |
| MoNA016629 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+2Na-H]+ | positive | - |
| MoNA016683 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
| MoNA016853 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+Na]+ | positive | - |
| HMDB0000630_ms_ms_858 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000630_ms_ms_859 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000630_ms_ms_860 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| BAF_UVA_POS000848 | XEVO-G2S | - | - | - | - | - | - |
| BAF_UVA_POS000849 | XEVO-G2S | - | - | - | - | - | - |
| BAF_UVA_POS000850 | XEVO-G2S | - | - | - | - | - | - |
| BAF_UVA_POS001403 | XEVO-G2S | - | - | - | - | - | - |
| HMDB0000630_c_ms_1215 | XEVO-G2S | GC-MS | - | - | - | - | - |
| HMDB0000630_c_ms_1295 | XEVO-G2S | GC-MS | - | - | - | - | - |