MoNA MS database records for Diosgenin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
NA003447 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100% (nominal) | [M+H]+ | positive | MS2 |
NA003448 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105% (nominal) | [M+H]+ | positive | MS2 |
NA002300 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10% (nominal) | [M+H]+ | positive | MS2 |
NA002301 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15% (nominal) | [M+H]+ | positive | MS2 |
NA002302 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20% (nominal) | [M+H]+ | positive | MS2 |
NA002303 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25% (nominal) | [M+H]+ | positive | MS2 |
NA002304 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30% (nominal) | [M+H]+ | positive | MS2 |
NA002697 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35% (nominal) | [M+H]+ | positive | MS2 |
NA002698 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40% (nominal) | [M+H]+ | positive | MS2 |
NA002699 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45% (nominal) | [M+H]+ | positive | MS2 |
NA002700 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50% (nominal) | [M+H]+ | positive | MS2 |
NA002701 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55% (nominal) | [M+H]+ | positive | MS2 |
NA003079 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60% (nominal) | [M+H]+ | positive | MS2 |
NA003080 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65% (nominal) | [M+H]+ | positive | MS2 |
NA003081 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70% (nominal) | [M+H]+ | positive | MS2 |
NA003082 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75% (nominal) | [M+H]+ | positive | MS2 |
NA003083 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80% (nominal) | [M+H]+ | positive | MS2 |
NA003444 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85% (nominal) | [M+H]+ | positive | MS2 |
NA003445 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90% (nominal) | [M+H]+ | positive | MS2 |
NA003446 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 95% (nominal) | [M+H]+ | positive | MS2 |
NGA00081 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00082 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00083 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00084 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007503 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007504 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007505 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
CCMSLIB00000855694 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000855696 | Maxis II HD Q-TOF Bruker | - | - | - | [M-H2O+H]+ | positive | MS2 |
VF-NPL-LTQ006551 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ006552 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS5 Composite |
Bruker_HCD_library001140 | Thermo Finnigan LTQ | - | - | - | [M+H]+ | positive | MS2 |
Bruker_HCD_library001139 | Thermo Finnigan LTQ | - | - | - | [M-H2O+H]+ | positive | MS2 |