MoNA MS database records for Gemfibrozil
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU269101 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
LU044851 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
EQ307101 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 15 (nominal) | [M+H]+ | positive | MS2 |
EQ307151 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 15 (nominal) | [M-H]- | negative | MS2 |
AU269102 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
LU044852 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
AU269103 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
EQ307102 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ307152 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 30 (nominal) | [M-H]- | negative | MS2 |
UF407753 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
AU269104 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
LU044853 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
EQ307103 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ307153 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 45 (nominal) | [M-H]- | negative | MS2 |
AU269105 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
UF407754 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
LU044854 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M-H]- | negative | MS2 |
EQ307104 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ307154 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 60 (nominal) | [M-H]- | negative | MS2 |
LU044855 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
EQ307105 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ307155 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 75 (nominal) | [M-H]- | negative | MS2 |
LU044856 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
EQ307106 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
EQ307156 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 90 (nominal) | [M-H]- | negative | MS2 |
AU269106 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 19.8-29.8 eV | [M+H]+ | positive | MS2 |