MoNA MS database records for Glucosaminate

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
MoNA024207Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
MoNA024242Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
MoNA033977Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA033976Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA033979Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA032050Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA035989Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA032052Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA035991Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA032054Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA035990Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA002022Agilent QTOF 6550LC-ESI-QTOF-10[M+H]+positiveMS2
MoNA002024Agilent QTOF 6550LC-ESI-QTOF-20[M+H]+positiveMS2
MoNA002023Agilent QTOF 6550LC-ESI-QTOF-40[M+H]+positiveMS2
KO000903API3000, Applied BiosystemsLC-ESI-QQ-10 V[M-H]-negativeMS2
KO000904API3000, Applied BiosystemsLC-ESI-QQ-20 V[M-H]-negativeMS2
KO000905API3000, Applied BiosystemsLC-ESI-QQ-30 V[M-H]-negativeMS2
KO000906API3000, Applied BiosystemsLC-ESI-QQ-40 V[M-H]-negativeMS2
KO000907API3000, Applied BiosystemsLC-ESI-QQ-50 V[M-H]-negativeMS2
KO003004API3000, Applied BiosystemsLC-ESI-QQ-10 V[M+H]+positiveMS2
KO003005API3000, Applied BiosystemsLC-ESI-QQ-20 V[M+H]+positiveMS2
KO003006API3000, Applied BiosystemsLC-ESI-QQ-30 V[M+H]+positiveMS2
KO003007API3000, Applied BiosystemsLC-ESI-QQ-40 V[M+H]+positiveMS2
KO003008API3000, Applied BiosystemsLC-ESI-QQ-50 V[M+H]+positiveMS2
FiehnLib000498Leco Pegasus IVGC-EI-TOF---positiveMS1
CCMSLIB00005464406Orbitrap---[M-H]-negativeMS2
CCMSLIB00005464380Orbitrap---[M+H]+positiveMS2
CCMSLIB00005464381Orbitrap---[M+Na]+positiveMS2
CCMSLIB00000578259Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00000578014Q-Exactive Plus---[M+H]+positiveMS2
CCMSLIB00005720750qTof---[M-H]-negativeMS2
CCMSLIB00005720455qTof---[M+H]+positiveMS2
VF-NPL-LTQ006543Thermo Finnigan LTQLinear Ion Trap-35M+HpositiveMS2
VF-NPL-LTQ006544Thermo Finnigan LTQLinear Ion Trap-35M+HpositiveMS2-MS5 Composite
MoNA037855Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MoNA037146Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA038539Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
EMBL-MCF_spec55946Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
EMBL-MCF_spec125850Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M+H]+positiveMS2
EMBL-MCF_spec125851Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M+H]+positiveMS2
MoNA016686XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-
Bruker_HCD_library001216XEVO-G2S---[M+H]+positiveMS2
BAF_UVA_POS000025XEVO-G2S------
BAF_UVA_POS000026XEVO-G2S------
BAF_UVA_POS000027XEVO-G2S------
BAF_UVA_POS000028XEVO-G2S------
  logo