MoNA MS database records for Harmaline

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
PR100517UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100070UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M+H]+positiveMS2
PR100069UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
BML00090Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-10 ev[M-H]-negativeMS2
BML00086Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-20 ev[M-H]-negativeMS2
BML00094Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-40 ev[M-H]-negativeMS2
BML81351Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---negativeMS1
BML81353Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF---negativeMS1
BML00065Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-10 ev[M+H]+positiveMS2
BML00072Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-20 ev[M+H]+positiveMS2
BML00079Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-40 ev[M+H]+positiveMS2
BML81350Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---positiveMS1
BML81352Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF---positiveMS1
KO001018API3000, Applied BiosystemsLC-ESI-QQ-10 V[M-H]-negativeMS2
KO001019API3000, Applied BiosystemsLC-ESI-QQ-20 V[M-H]-negativeMS2
KO001020API3000, Applied BiosystemsLC-ESI-QQ-30 V[M-H]-negativeMS2
KO001021API3000, Applied BiosystemsLC-ESI-QQ-40 V[M-H]-negativeMS2
KO001022API3000, Applied BiosystemsLC-ESI-QQ-50 V[M-H]-negativeMS2
KO003098API3000, Applied BiosystemsLC-ESI-QQ-10 V[M+H]+positiveMS2
KO003099API3000, Applied BiosystemsLC-ESI-QQ-20 V[M+H]+positiveMS2
KO003100API3000, Applied BiosystemsLC-ESI-QQ-30 V[M+H]+positiveMS2
KO003101API3000, Applied BiosystemsLC-ESI-QQ-40 V[M+H]+positiveMS2
KO003102API3000, Applied BiosystemsLC-ESI-QQ-50 V[M+H]+positiveMS2
KO008994LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.95[M+H]+positiveMS2
KO008997LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.60/0.60[M+H]+positiveMS3
KO008995LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.80/0.65[M+H]+positiveMS3
KO008996LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.80/0.70[M+H]+positiveMS3
KZ000213Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
PR010121Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
VF-NPL-LTQ000883Thermo Finnigan LTQLinear Ion Trap-35M+HpositiveMS2
VF-NPL-LTQ007575Thermo Finnigan LTQLinear Ion Trap-35M+HpositiveMS2
VF-NPL-LTQ000884Thermo Finnigan LTQLinear Ion Trap-35M+HpositiveMS2-MS5 Composite
VF-NPL-LTQ007576Thermo Finnigan LTQLinear Ion Trap-35M+HpositiveMS2-MS5 Composite
VF-NPL-QEHF026677Thermo Q Exactive HFESI-QFT-35HCD[M-H]-negativeMS2
VF-NPL-QEHF026678Thermo Q Exactive HFESI-QFT-45HCD[M-H]-negativeMS2
VF-NPL-QEHF026679Thermo Q Exactive HFESI-QFT-65HCD[M-H]-negativeMS2
VF-NPL-QEHF026674Thermo Q Exactive HFESI-QFT-35HCD[M+H]+positiveMS2
VF-NPL-QEHF026675Thermo Q Exactive HFESI-QFT-45HCD[M+H]+positiveMS2
VF-NPL-QEHF026676Thermo Q Exactive HFESI-QFT-65HCD[M+H]+positiveMS2
VF-NPL-QEHF026683Thermo Q Exactive HFESI-QFT-35HCD[M+K]+positiveMS2
VF-NPL-QEHF026684Thermo Q Exactive HFESI-QFT-45HCD[M+K]+positiveMS2
VF-NPL-QEHF026685Thermo Q Exactive HFESI-QFT-65HCD[M+K]+positiveMS2
VF-NPL-QEHF026680Thermo Q Exactive HFESI-QFT-35HCD[M+Na]+positiveMS2
VF-NPL-QEHF026681Thermo Q Exactive HFESI-QFT-45HCD[M+Na]+positiveMS2
VF-NPL-QEHF026682Thermo Q Exactive HFESI-QFT-65HCD[M+Na]+positiveMS2
VF-NPL-QEHF026686Thermo Q Exactive HFESI-QFT-35HCD[M+NH4]+positiveMS2
VF-NPL-QEHF026687Thermo Q Exactive HFESI-QFT-45HCD[M+NH4]+positiveMS2
VF-NPL-QEHF026688Thermo Q Exactive HFESI-QFT-65HCD[M+NH4]+positiveMS2
MoNA002564Thermo Q Exactive HF----positiveMS1
  logo