MoNA MS database records for Indoleacetic acid
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA001251 | Sciex Triple TOF 6600 | - | Electrospray Ionization (ESI) | -35 V | [M-H]- | negative | MS2 |
PB000510 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB000511 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PB000512 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PB000513 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB000514 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU279601 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU279603 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU279604 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU279605 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU279606 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 17.1-25.7 eV | [M+H]+ | positive | MS2 |
MT000032 | LTQ XL, Thermo Finnigan | LC-ESI-IT | ESI | 40 | [M+H]+ | positive | MS2 |
RP016611 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP016612 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
RP016601 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP016602 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP016603 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
LU019051 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
LU019052 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
LU019053 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
LU019054 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M-H]- | negative | MS2 |
LU019055 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
LU019056 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
PT202550 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT102553 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M+H]+ | positive | MS2 |
PT102550 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
MoNA023914 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA023919 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS025501 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS025502 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS025503 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS025504 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS025505 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PR100570 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100149 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M+H]+ | positive | MS2 |
PR100148 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR020128 | UPLC Waters, Quattro Ultima Pt... | LC-ESI-QQ | ESI | 10.0 eV | [M+H]+ | positive | MS2 |
MoNA010018 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010021 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010019 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010022 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010017 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010020 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA034425 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035080 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034426 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA035083 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA032896 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036602 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032897 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036601 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032898 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036604 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
KO001226 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO001227 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO001228 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO001229 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO001230 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO003212 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO003213 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO003214 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO003215 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO003216 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
JP001408 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
FiehnLib000941 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
NUTRI-METAB-FEM-NEG001902 | Orbitrap | - | - | - | 2M-2H+Na | negative | - |
NUTRI-METAB-FEM-NEG001905 | Orbitrap | - | - | - | 2M-2H+Na | negative | - |
NUTRI-METAB-FEM-NEG001907 | Orbitrap | - | - | - | 2M-2H+Na | negative | - |
NUTRI-METAB-FEM-NEG001910 | Orbitrap | - | - | - | 2M-2H+Na | negative | - |
NUTRI-METAB-FEM-NEG001913 | Orbitrap | - | - | - | 2M-2H+Na | negative | - |
NUTRI-METAB-FEM-NEG001901 | Orbitrap | - | - | - | 2M-H | negative | - |
NUTRI-METAB-FEM-NEG001904 | Orbitrap | - | - | - | 2M-H | negative | - |
NUTRI-METAB-FEM-NEG001906 | Orbitrap | - | - | - | 2M-H | negative | - |
NUTRI-METAB-FEM-NEG001909 | Orbitrap | - | - | - | 2M-H | negative | - |
NUTRI-METAB-FEM-NEG001912 | Orbitrap | - | - | - | 2M-H | negative | - |
NUTRI-METAB-FEM-NEG001915 | Orbitrap | - | - | - | 2M-H | negative | - |
NUTRI-METAB-FEM-NEG001243 | Orbitrap | - | - | - | M-H | negative | - |
NUTRI-METAB-FEM-NEG001244 | Orbitrap | - | - | - | M-H | negative | - |
NUTRI-METAB-FEM-NEG001903 | Orbitrap | - | - | - | M-H | negative | - |
NUTRI-METAB-FEM-NEG001908 | Orbitrap | - | - | - | M-H | negative | - |
NUTRI-METAB-FEM-NEG001911 | Orbitrap | - | - | - | M-H | negative | - |
NUTRI-METAB-FEM-NEG001914 | Orbitrap | - | - | - | M-H | negative | - |
CCMSLIB00005464240 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464251 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005724307 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005724329 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
MoNA043154 | Orbitrap | - | - | - | M+H | positive | - |
MoNA043155 | Orbitrap | - | - | - | M+H | positive | - |
MoNA043156 | Orbitrap | - | - | - | M+H | positive | - |
MoNA043157 | Orbitrap | - | - | - | M+H | positive | - |
MoNA043158 | Orbitrap | - | - | - | M+H | positive | - |
MoNA043159 | Orbitrap | - | - | - | M+H | positive | - |
CCMSLIB00005464241 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005464252 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
KZ000036 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
KZ000142 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
KZ000143 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
KZ000144 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010197 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010198 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000578058 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720802 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720836 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720197 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720507 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720541 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC002762 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC001662 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC000965 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038009 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038179 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000080 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037280 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037427 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038645 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038745 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec79775 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
MoNA016719 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA016720 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
HMDB0000197_ms_ms_319 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000197_ms_ms_320 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000197_ms_ms_321 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000197_c_ms_1670 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000197_c_ms_1705 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000197_ei_ms_597 | XEVO-G2S | - | - | - | - | - | - |