MoNA MS database records for Irbesartan
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU209451 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
AU209452 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
AU209453 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
AU209454 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
AU209455 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M-H]- | negative | MS2 |
EA277451 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M-H]- | negative | MS2 |
EA277452 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M-H]- | negative | MS2 |
EA277453 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M-H]- | negative | MS2 |
EA277454 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M-H]- | negative | MS2 |
EA277455 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M-H]- | negative | MS2 |
EA277456 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M-H]- | negative | MS2 |
EA277457 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M-H]- | negative | MS2 |
EA277458 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M-H]- | negative | MS2 |
EA277459 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M-H]- | negative | MS2 |
EA277460 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M-H]- | negative | MS2 |
EA277461 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M-H]- | negative | MS2 |
EA277462 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M-H]- | negative | MS2 |
EA277463 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M-H]- | negative | MS2 |
EA277464 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M-H]- | negative | MS2 |
FiehnHILIC001269 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC002772 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
MoNA035541 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035542 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA035543 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA038359 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
SM818756 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
AU209402 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU209403 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU209404 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU209405 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU209407 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU209408 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU209409 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU209410 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU209411 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
CCMSLIB00000078173 | qTof | - | - | - | [M+H]+ | positive | MS2 |
EA277401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA277402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA277403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA277404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA277405 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA277406 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA277407 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA277408 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA277409 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA277410 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA277411 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA277412 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA277413 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA277414 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
FiehnHILIC000447 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC002018 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
KW107401 | Orbitrap Classic, Thermo Scien... | LC-ESI-ITFT | ESI | 35 eV IT-MS | [M+H]+ | positive | MS2 |
KW107402 | Orbitrap Classic, Thermo Scien... | LC-ESI-ITFT | ESI | 35 eV FT-MS | [M+H]+ | positive | MS2 |
KW107403 | Orbitrap Classic, Thermo Scien... | LC-ESI-ITFT | ESI | 35 eV FT-MS II | [M+H]+ | positive | MS2 |
KW107404 | Orbitrap Classic, Thermo Scien... | LC-ESI-ITFT | ESI | 65 eV FT-MS | [M+H]+ | positive | MS2 |
MoNA036852 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036855 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036858 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA038853 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
SM818701 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
CCMSLIB00000079128 | qTof | - | - | - | - | - | - |
WA001036 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001037 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001038 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001039 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001040 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001041 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA001042 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |