MoNA MS database records for L-Glutamic acid
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
BML01298 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML81311 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML81313 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
MoNA010615 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010616 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010617 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010618 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010619 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010620 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA011064 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA011065 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA011066 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA018090 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA018091 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
OUF01012 | Agilent 7000B QqQMS, Agilent; ... | GC-EI-QQ | - | - | - | positive | MS1 |
MoNA031889 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA031890 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA031891 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032284 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA032285 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032286 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA034252 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034253 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034258 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA034910 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034911 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034914 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA036198 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036201 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036202 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA001975 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
PM000933 | API 2000 | QqQ | ESI | 24 | [M+H]+ | positive | MS2 |
PM000985 | API 2000 | QqQ | ESI | -14 | [M-H]- | negative | MS2 |
PM002317 | API 3000 | QqQ | ESI | 10->40V | [M+H]+ | positive | MS2 |
KO000848 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO000849 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO000850 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO000851 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO000852 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO002949 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002950 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002951 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002952 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002953 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
PB000461 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB000463 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PR030006 | CE-system connected to 6210 Ti... | CE-ESI-TOF | ESI | - | [M+H]+ | positive | MS1 |
GLS00031 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
FiehnLib000386 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000441 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0060475_c_ms_102430 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
KNA00073 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00074 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00276 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00277 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H2O+H]+ | positive | MS2 |
KNA00278 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00495 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
KNA00497 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00672 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
KNA00674 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
CE000653 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 20.0eV | [M+H]+ | positive | MS2 |
CE000655 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 40.0eV | [M+H]+ | positive | MS2 |
CE000656 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 50.0eV | [M+H]+ | positive | MS2 |
CE000658 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 5.0eV | [M+H]+ | positive | MS2 |
CE000660 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 55.0eV | [M+H]+ | positive | MS2 |
CE000661 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 45.0eV | [M+H]+ | positive | MS2 |
CE000662 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 10.0eV | [M+H]+ | positive | MS2 |
RP001401 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP001402 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP001403 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
RP001411 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP001412 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
CCMSLIB00000479623 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00003740029 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463979 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464095 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
KZ000224 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
OUF00248 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010058 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00005720323 | qTof | - | - | - | [M+H]+ | positive | MS2 |
PT102720 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT202720 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
FiehnHILIC001963 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002731 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC000388 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001220 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA037042 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037232 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037742 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA037948 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038484 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038614 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec159221 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec159266 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec353854 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec353862 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec383226 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec383229 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec383235 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H2O-H]- | negative | MS2 |
MoNA024312 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA024362 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS027201 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS027202 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS027203 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS027204 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PR100162 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100580 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
HMDB0000148_c_ms_1228 | UPLC Q-Tof Premier, Waters | GC-MS | - | - | - | - | - |
HMDB0000148_c_ms_1296 | UPLC Q-Tof Premier, Waters | GC-MS | - | - | - | - | - |
HMDB0000148_ms_ms_221 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | - |
HMDB0000148_ms_ms_222 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | - |
HMDB0000148_ms_ms_223 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | - |
MoNA002372 | UPLC Q-Tof Premier, Waters | - | - | - | - | positive | MS1 |
MoNA002456 | UPLC Q-Tof Premier, Waters | - | - | - | - | positive | MS1 |
MoNA003293 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 10(NCE) | [M+H]+ | positive | MS2 |
MoNA003294 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 30(NCE) | [M+H]+ | positive | MS2 |
MoNA003295 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 50(NCE) | [M+H]+ | positive | MS2 |
MoNA003296 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 70(NCE) | [M+H]+ | positive | MS2 |
MoNA003297 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 90(NCE) | [M+H]+ | positive | MS2 |
MoNA003298 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 40(NCE) | [M+H]+ | positive | MS2 |