MoNA MS database records for L-Isoleucine
| Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|---|
| MoNA010394 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| MoNA010397 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| PS028001 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
| RP000801 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
| RP000811 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
| MoNA032097 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA032704 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA034058 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
| MoNA034912 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
| MoNA035863 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA036034 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA003311 | Agilent qTOF 6545 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 10(NCE) | [M+H]+ | positive | MS2 |
| KO001175 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
| KO003172 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
| PM018187 | QTOF Premier | Q-TOF | ESI | 15->55V | [M+H]+ | positive | MS2 |
| PM000925 | API 2000 | QqQ | ESI | 16 | [M+H]+ | positive | MS2 |
| PS028002 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
| RP000802 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
| MoNA032103 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA032706 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA035862 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA036035 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| KO001176 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
| KO003173 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec23096 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 28.33 eV | [M-H]- | negative | MS2 |
| MoNA010395 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| MoNA010398 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| PS028003 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec352816 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec352821 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
| MoNA003312 | Thermo Q-Exactive Plus | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 30(NCE) | [M+H]+ | positive | MS2 |
| KO001177 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
| KO003174 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec370588 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
| EMBL-MCF_spec370601 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
| EMBL-MCF_spec370606 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
| EMBL-MCF_spec377602 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
| EMBL-MCF_spec377605 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
| FiehnHILIC002022 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
| KNA00041 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
| KNA00042 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
| KNA00043 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
| KNA00320 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
| KNA00321 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
| KNA00322 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
| RP000803 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
| MoNA032101 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA032707 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA035861 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA036039 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA003313 | Agilent qTOF 6545 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 40(NCE) | [M+H]+ | positive | MS2 |
| KO001178 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
| KO003175 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
| MoNA003314 | API3000, Applied Biosystems | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 50(NCE) | [M+H]+ | positive | MS2 |
| KO001179 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
| KO003176 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
| MoNA016744 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
| MoNA003315 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 70(NCE) | [M+H]+ | positive | MS2 |
| MoNA003316 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 90(NCE) | [M+H]+ | positive | MS2 |
| FiehnHILIC000452 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| FiehnHILIC001272 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA037047 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA037164 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA037745 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA037883 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA038557 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA024313 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
| MoNA024361 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
| CCMSLIB00000577889 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00000578107 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
| CCMSLIB00005463980 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
| CCMSLIB00005464055 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00005720610 | qTof | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00005720628 | qTof | - | - | - | [M-H]- | negative | MS2 |
| FiehnLib000726 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| FiehnLib001035 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| GLS00013 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
| HMDB0000172_ei_ms_1294 | GCMS-2010 Plus, Shimadzu | - | - | - | - | - | - |
| HMDB0000172_ms_ms_271 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000172_ms_ms_272 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000172_ms_ms_273 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
| KZ000231 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| KZ000232 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| KZ000233 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| MoNA002393 | Pegasus III TOF-MS system, Lec... | - | - | - | - | positive | MS1 |
| MoNA002479 | Pegasus III TOF-MS system, Lec... | - | - | - | - | positive | MS1 |
| MoNA010393 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| MoNA010396 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| OUF00312 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| OUF01004 | Agilent 7000B QqQMS, Agilent; ... | GC-EI-QQ | - | - | - | positive | MS1 |
| PR010061 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| PR030010 | CE-system connected to 6210 Ti... | CE-ESI-TOF | ESI | - | [M+H]+ | positive | MS1 |