MoNA MS database records for L-Leucine
| Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|---|
| MoNA010369 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| MoNA010370 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| MoNA010371 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| MoNA010372 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| MoNA010373 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| MoNA010374 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| MoNA011143 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
| MoNA011144 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
| MoNA011145 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
| MoNA011146 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
| MoNA017610 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
| OUF01003 | Agilent 7000B QqQMS, Agilent; ... | GC-EI-QQ | - | - | - | positive | MS1 |
| MoNA032617 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA032618 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA032619 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA032701 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA032702 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA032703 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA034746 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
| MoNA034915 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
| MoNA035857 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA035858 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA035859 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA036436 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA036438 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA036439 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| PM000923 | API 2000 | QqQ | ESI | 14 | [M+H]+ | positive | MS2 |
| KO001261 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
| KO001262 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
| KO001263 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
| KO001264 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
| KO003277 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
| KO003278 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
| KO003279 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
| KO003280 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
| KO003281 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
| PR030011 | CE-system connected to 6210 Ti... | CE-ESI-TOF | ESI | - | [M+H]+ | positive | MS1 |
| GLS00004 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
| JP005747 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
| FiehnLib000896 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| KNA00126 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
| KNA00361 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
| RP000601 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
| RP000602 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
| RP000603 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
| RP000611 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
| CCMSLIB00005463956 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00005464086 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
| KZ000049 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| KZ000158 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| KZ000159 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| OUF00305 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| PR010034 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| PT100520 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
| PT200520 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
| FiehnHILIC002047 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
| FiehnHILIC002797 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
| FiehnHILIC000475 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| FiehnHILIC001296 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA037044 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA037379 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA038126 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA038704 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA024138 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
| MoNA024189 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
| PS005201 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
| PS005202 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
| PS005203 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
| PS005204 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
| PS005205 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
| PR100496 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
| HMDB0000687_ms_ms_951 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000687_ms_ms_952 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000687_ms_ms_953 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | - |
| HMDB0062203_ms_ms_951 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | MS2 |
| HMDB0062203_ms_ms_952 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | MS2 |
| HMDB0062203_ms_ms_953 | UPLC Q-Tof Premier, Waters | Quattro_QQQ | - | - | - | positive | MS2 |
| MoNA002384 | UPLC Q-Tof Premier, Waters | - | - | - | - | positive | MS1 |
| MoNA003317 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 10(NCE) | [M+H]+ | positive | MS2 |
| MoNA003318 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 30(NCE) | [M+H]+ | positive | MS2 |
| MoNA003319 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 40(NCE) | [M+H]+ | positive | MS2 |
| MoNA003320 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 50(NCE) | [M+H]+ | positive | MS2 |
| MoNA003321 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 70(NCE) | [M+H]+ | positive | MS2 |
| MoNA003322 | UPLC Q-Tof Premier, Waters | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 90(NCE) | [M+H]+ | positive | MS2 |