MoNA MS database records for LINURON
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU232357 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
AU232358 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
AU232359 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
AU232360 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
AU232301 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU232302 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU232303 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU232304 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU232305 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU232306 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 19.8-29.6 eV | [M+H]+ | positive | MS2 |
EA016002 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA016008 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA016003 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA016009 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
UF403103 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
EA016001 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA016014 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA016004 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA016010 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
UF403101 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF403104 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
EA016005 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA016011 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA016006 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA016012 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
UF403102 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
EA016007 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA016013 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
LU004851 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
LU004852 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
LU004853 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
LU004854 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M-H]- | negative | MS2 |
LU004855 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
LU004856 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
SM841202 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
CCMSLIB00001058462 | Maxis HD qTOF | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00001058258 | Q-Exactive Plus Orbitrap Res 1... | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00001058962 | Q-Exactive Plus Orbitrap Res 7... | - | - | - | [M+H]+ | positive | MS2 |