MoNA MS database records for Phloretin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PB000681 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB000682 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB000701 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB000702 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M+H]+ | positive | MS2 |
BML00590 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML00595 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML00600 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
BML81931 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML81933 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML00573 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00579 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00585 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML81930 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML81932 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
VF-NPL-QTOF004666 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009271 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004667 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009272 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004668 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009273 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF001955 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001956 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001957 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF004669 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009274 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004670 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009275 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004671 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009276 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001958 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001959 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001960 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
TY000157 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | - | negative | MS1 |
TY000158 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | [M+H]+ | positive | MS2 |
TY000156 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | - | positive | MS1 |
FiehnLib000836 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0003306_c_ms_99802 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
FiehnHILIC002928 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC002251 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000081 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000082 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS3 Composite |
VF-NPL-LTQ000079 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000080 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-QEHF000145 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000146 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000147 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
FiehnHILIC001443 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
VF-NPL-QEHF000148 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000149 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000150 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
FiehnHILIC000682 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
HMDB0003306_ms_ms_2233 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | positive | - |
HMDB0003306_ms_ms_2234 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | positive | - |
HMDB0003306_ms_ms_2235 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | positive | - |