MoNA MS database records for Progesterone
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
JP003430 | JEOL JMS-01-SG-2 | EI-B | - | - | [M]+* | positive | MS1 |
JP007249 | HITACHI M-52 | EI-B | - | - | [M]+* | positive | MS1 |
JP011649 | HITACHI M-2500 | EI-B | - | - | [M]+* | positive | MS1 |
VF-NPL-QEHF000220 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000221 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000222 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000223 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000224 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000225 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001979 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001980 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001981 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
FiehnLib000342 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0001830_c_ms_2212 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0001830_c_ms_2217 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
BML82007 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
FFF00200 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00201 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00202 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00203 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00204 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00205 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00206 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS1 |
UF415101 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF415102 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF415103 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF415104 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
EQ325502 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ325503 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ325504 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ325505 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ325506 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
FiehnHILIC000707 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
LU055001 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU055002 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU055003 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU055004 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU055005 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M+H]+ | positive | MS2 |
LU055006 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M+H]+ | positive | MS2 |
SM872401 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
CB000367 | ABSciex API3200 LC/MS system | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS1 |
NGA01737 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA01738 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA01739 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA01740 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
AU107701 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 21.9-32.9 eV | [M+H]+ | positive | MS2 |
AU107702 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU107703 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU107704 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU107705 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU107706 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU107730 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+Na]+ | positive | MS2 |
AU107731 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+Na]+ | positive | MS2 |
AU107732 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+Na]+ | positive | MS2 |
AU107733 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+Na]+ | positive | MS2 |
BML82005 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
FiehnHILIC002276 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004730 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004731 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004732 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009398 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009399 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009400 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000093 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ000094 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS3 Composite |
HMDB0001830_ms_ms_1684 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
HMDB0001830_ms_ms_1685 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
HMDB0001830_ms_ms_1686 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
Bruker_HCD_library001295 | Thermo Finnigan LTQ | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000078244 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000079191 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000084845 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000085881 | qTof | - | - | - | [M+H]+ | positive | MS2 |
HMDB0001830_ei_ms_469 | qTof | - | - | - | - | - | - |
MoNA041698 | Agilent 6560 | - | - | 20 | [M+H]+ | positive | - |
MoNA041769 | Agilent 6560 | - | - | 40 | [M+H]+ | positive | - |