MoNA MS database records for SENECIPHYLLINE
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PM014309 | API 365 | QqQ | ESI | 41V | [M+H]+ | positive | MS2 |
PR310585 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
NA003582 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100% (nominal) | [M+H]+ | positive | MS2 |
NA003583 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105% (nominal) | [M+H]+ | positive | MS2 |
NA002439 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10% (nominal) | [M+H]+ | positive | MS2 |
NA002440 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15% (nominal) | [M+H]+ | positive | MS2 |
NA002441 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20% (nominal) | [M+H]+ | positive | MS2 |
NA002442 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25% (nominal) | [M+H]+ | positive | MS2 |
NA002443 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30% (nominal) | [M+H]+ | positive | MS2 |
NA002834 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35% (nominal) | [M+H]+ | positive | MS2 |
NA002835 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40% (nominal) | [M+H]+ | positive | MS2 |
NA002836 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45% (nominal) | [M+H]+ | positive | MS2 |
NA002837 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50% (nominal) | [M+H]+ | positive | MS2 |
NA002838 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55% (nominal) | [M+H]+ | positive | MS2 |
NA003214 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60% (nominal) | [M+H]+ | positive | MS2 |
NA003215 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65% (nominal) | [M+H]+ | positive | MS2 |
NA003216 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70% (nominal) | [M+H]+ | positive | MS2 |
NA003217 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75% (nominal) | [M+H]+ | positive | MS2 |
NA003218 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80% (nominal) | [M+H]+ | positive | MS2 |
NA003579 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85% (nominal) | [M+H]+ | positive | MS2 |
NA003580 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90% (nominal) | [M+H]+ | positive | MS2 |
NA003581 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 95% (nominal) | [M+H]+ | positive | MS2 |
FIO00240 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO00241 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO00242 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO00243 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
FIO00244 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
BML00779 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00790 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00801 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML82160 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML82162 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
RIKENPlaSMA001186 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001190 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001201 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001205 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001216 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001220 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001193 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001209 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001224 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001197 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001212 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA001228 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |