MoNA MS database records for Sinapic acid

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
PR309001LC, Waters Acquity UPLC System...LC-ESI-QTOFESI6V[M-H]-negativeMS2
PR311176LC, Waters Acquity UPLC System...LC-ESI-QTOFESI6V[M+H]+positiveMS2
RP017411maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI10[M-H]-negativeMS2
RP017412maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI20[M-H]-negativeMS2
RP017413maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI40[M-H]-negativeMS2
RP017401maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI10[M+H]+positiveMS2
RP017402maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI20[M+H]+positiveMS2
RP017403maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI40[M+H]+positiveMS2
PT201560Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT210880Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT101560Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
PT110880Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
PS045307TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS108807TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS015601TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS045301TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS108801TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS015602TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS045302TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS108802TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PR100527UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100984UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR020014UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI5.0 V[M+H]+positiveMS1
PR100093UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
PR101042UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
VF-NPL-QTOF009685Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M-H]-negativeMS2
VF-NPL-QTOF009686Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M-H]-negativeMS2
VF-NPL-QTOF009687Agilent 6530 Q-TOFLC-ESI-QTOF-40 V[M-H]-negativeMS2
KO001822API3000, Applied BiosystemsLC-ESI-QQ-10 V[M-H]-negativeMS2
KO001823API3000, Applied BiosystemsLC-ESI-QQ-20 V[M-H]-negativeMS2
KO001824API3000, Applied BiosystemsLC-ESI-QQ-30 V[M-H]-negativeMS2
KO001825API3000, Applied BiosystemsLC-ESI-QQ-40 V[M-H]-negativeMS2
KO001826API3000, Applied BiosystemsLC-ESI-QQ-50 V[M-H]-negativeMS2
JP007240HITACHI M-52EI-B--[M]+*positiveMS1
FiehnLib000178Leco Pegasus IVGC-EI-TOF---positiveMS1
FiehnLib000179Leco Pegasus IVGC-EI-TOF---positiveMS1
MoNA043720Orbitrap---M+Hpositive-
MoNA043722Orbitrap---M+Hpositive-
MoNA043721Orbitrap---M-H2O+Hpositive-
MoNA043723Orbitrap---M-H2O+Hpositive-
KZ000073Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
OUF00459Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
PR010129Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
PR010130Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
CCMSLIB00000078889qTof---[M-H]-negativeMS2
CCMSLIB00000078855qTof---[M+H]+positiveMS2
CCMSLIB00000077199Q-TOF---[M+H]+positiveMS2
FiehnHILIC002986SCIEX TripleTOF 6600LC-ESI-QTOF-35 eV[M-H]-negativeMS2
VF-NPL-QEHF011647Thermo Q Exactive HFESI-QFT-35HCD[M-H]-negativeMS2
VF-NPL-QEHF011648Thermo Q Exactive HFESI-QFT-45HCD[M-H]-negativeMS2
VF-NPL-QEHF011649Thermo Q Exactive HFESI-QFT-65HCD[M-H]-negativeMS2
FiehnHILIC001512Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
VF-NPL-QEHF011659Thermo Q Exactive HFESI-QFT-35HCD[M+H]+positiveMS2
VF-NPL-QEHF011660Thermo Q Exactive HFESI-QFT-45HCD[M+H]+positiveMS2
VF-NPL-QEHF011661Thermo Q Exactive HFESI-QFT-65HCD[M+H]+positiveMS2
FiehnHILIC000764Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
VF-NPL-QEHF011653Thermo Q Exactive HFESI-QFT-35HCD[M+K]+positiveMS2
VF-NPL-QEHF011654Thermo Q Exactive HFESI-QFT-45HCD[M+K]+positiveMS2
VF-NPL-QEHF011655Thermo Q Exactive HFESI-QFT-65HCD[M+K]+positiveMS2
VF-NPL-QEHF011650Thermo Q Exactive HFESI-QFT-35HCD[M+Na]+positiveMS2
VF-NPL-QEHF011651Thermo Q Exactive HFESI-QFT-45HCD[M+Na]+positiveMS2
VF-NPL-QEHF011652Thermo Q Exactive HFESI-QFT-65HCD[M+Na]+positiveMS2
VF-NPL-QEHF011656Thermo Q Exactive HFESI-QFT-35HCD[M+NH4]+positiveMS2
VF-NPL-QEHF011657Thermo Q Exactive HFESI-QFT-45HCD[M+NH4]+positiveMS2
VF-NPL-QEHF011658Thermo Q Exactive HFESI-QFT-65HCD[M+NH4]+positiveMS2
MCH00014Voyager DE-PRO, Applied Biosys...MALDI-TOF---negativeMS1
MCH00015Voyager DE-PRO, Applied Biosys...MALDI-TOF---positiveMS1
RIKENPlaSMA007062Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA007065Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA007073Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA007075Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA007083Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA007086Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA007068Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA007078Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA007089Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA007071Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA007081Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA007092Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA003342Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA003345Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA003354Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA003357Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA003366Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA003369Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA003348Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA003360Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA003372Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA003351Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA003363Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA003375Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
Bruker_HCD_library000431Waters Xevo G2 Q-Tof---[M-H]-negativeMS2
HMDB0032616_c_ms_1892Waters Xevo G2 Q-TofGC-MS-----
HMDB0032616_ei_ms_1792Waters Xevo G2 Q-Tof------