MoNA MS database records for Syringin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PS113505 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009769 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009770 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009771 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009766 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+NH4]+ | positive | MS2 |
VF-NPL-QTOF009767 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+NH4]+ | positive | MS2 |
VF-NPL-QTOF009768 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+NH4]+ | positive | MS2 |
TY000098 | Shimadzu LC20A-IT-TOFMS | LC-ESI-ITTOF | - | - | [M+CH3COOH-H]- | negative | MS1 |
VF-NPL-LTQ002041 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+NH4 | positive | MS2 |
VF-NPL-LTQ002042 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+NH4 | positive | MS2-MS3 Composite |
VF-NPL-QEHF005617 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF005618 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF005619 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF005629 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF005630 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF005631 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF005623 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF005624 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF005625 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF005620 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF005621 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF005622 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF005626 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF005627 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF005628 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |
Bruker_HCD_library000383 | Thermo Q Exactive HF | - | - | - | [M+C2H4O2-H]- | negative | MS2 |
EAD001109 | Thermo Q Exactive HF | - | - | - | [M+H]+ | - | - |
EAD001284 | Thermo Q Exactive HF | - | - | - | [M+Na]+ | - | - |
EAD001241 | Thermo Q Exactive HF | - | - | - | [M+NH4]+ | - | - |