MoNA MS database records for Tryptophanol

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
PR310882LC, Waters Acquity UPLC System...LC-ESI-QTOFESI6V[M+H-H2O]+positiveMS2
MoNA023856Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
MoNA023895Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M+H]+positiveMS2
MoNA034368Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA034371Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA034372Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA032357Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA036257Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA032358Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA036260Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA032359Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA036263Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
KO001201API3000, Applied BiosystemsLC-ESI-QQ-10 V[M-H]-negativeMS2
KO001202API3000, Applied BiosystemsLC-ESI-QQ-20 V[M-H]-negativeMS2
KO001203API3000, Applied BiosystemsLC-ESI-QQ-30 V[M-H]-negativeMS2
KO001204API3000, Applied BiosystemsLC-ESI-QQ-40 V[M-H]-negativeMS2
KO001205API3000, Applied BiosystemsLC-ESI-QQ-50 V[M-H]-negativeMS2
FiehnLib000925Leco Pegasus IVGC-EI-TOF---positiveMS1
CCMSLIB00005464117Orbitrap---[M+H]+positiveMS2
MoNA043777Orbitrap---M+Hpositive-
MoNA043779Orbitrap---M+Hpositive-
MoNA043782Orbitrap---M+Hpositive-
MoNA043783Orbitrap---M+Hpositive-
MoNA043785Orbitrap---M+Hpositive-
MoNA043786Orbitrap---M+Hpositive-
CCMSLIB00005464118Orbitrap---[M-H2O+H]+positiveMS2
MoNA043778Orbitrap---M-H2O+Hpositive-
MoNA043780Orbitrap---M-H2O+Hpositive-
MoNA043781Orbitrap---M-H2O+Hpositive-
MoNA043784Orbitrap---M-H2O+Hpositive-
CCMSLIB00005464119Orbitrap---[M+Na]+positiveMS2
CCMSLIB00000578313Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00004752866qTof---[M+H]+positiveMS2
CCMSLIB00005720199qTof---[M+H]+positiveMS2
CCMSLIB00005720513qTof---[M+H]+positiveMS2
MoNA037992Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MoNA037263Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA038634Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
EMBL-MCF_spec73109Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
MoNA016807XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-
HMDB0003447_ms_ms_2313XEVO-G2SQuattro_QQQ---positive-
HMDB0003447_ms_ms_2314XEVO-G2SQuattro_QQQ---positive-
HMDB0003447_ms_ms_2315XEVO-G2SQuattro_QQQ---positive-
HMDB0003447_c_ms_1627XEVO-G2SGC-MS-----
HMDB0003447_ei_ms_1838XEVO-G2S------