MoNA MS database records for Uridine 5'-monophosphate
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA017598 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA017599 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA017600 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
MoNA017601 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
PT203720 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
MoNA024288 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA024276 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS037207 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS037208 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS037210 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M-H]- | negative | MS2 |
PS037211 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M-H]- | negative | MS2 |
PS037212 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M-H]- | negative | MS2 |
PS037201 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS037202 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS037203 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS037204 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS037205 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS037206 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PR100623 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
BML82306 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
MoNA011402 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA011403 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA011404 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA011405 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA034642 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034641 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034643 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA036368 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036373 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036372 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA002222 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA002224 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA002225 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
CCMSLIB00005464512 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000479749 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464582 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464583 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00000578124 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720338 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC001559 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038084 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000836 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038682 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec393968 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec393978 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec393984 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec25148 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec394640 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M-H2O-H]- | negative | MS2 |
EMBL-MCF_spec394643 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M-H2O-H]- | negative | MS2 |
EMBL-MCF_spec98587 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
HMDB0000288_ms_ms_486 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000288_ms_ms_487 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000288_ms_ms_488 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000288_c_ms_2175 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |