MoNA MS database records for Pyridoxamine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA001947 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA011301 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
PS009901 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA032132 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA034086 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
KO001725 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
MoNA001949 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA011302 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
PS009902 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA032139 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA034087 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
KO001726 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
MoNA011303 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
PS009903 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
KO001727 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
PR100057 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M+H]+ | positive | MS2 |
PT100993 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M+H]+ | positive | MS2 |
EMBL-MCF_spec120647 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec120690 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec120696 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec50210 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
MoNA001948 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA011304 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
PS009904 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA032136 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA034085 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
KO001728 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO001729 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
MoNA016944 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
FiehnHILIC000719 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001473 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA037178 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA024127 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
PT100990 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT200990 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PR100056 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100512 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
BAF_UVA_POS000210 | UPLC Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS000211 | UPLC Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS000212 | UPLC Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS000213 | UPLC Q-Tof Premier, Waters | - | - | - | - | - | - |
BAF_UVA_POS000884 | UPLC Q-Tof Premier, Waters | - | - | - | - | - | - |
CCMSLIB00000479731 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000577987 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578232 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464185 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464186 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005464259 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720429 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720728 | qTof | - | - | - | [M-H]- | negative | MS2 |
HMDB0001431_c_ms_1667 | qTof | GC-MS | - | - | - | - | - |
HMDB0001431_ms_ms_1574 | qTof | Quattro_QQQ | - | - | - | positive | - |
HMDB0001431_ms_ms_1575 | qTof | Quattro_QQQ | - | - | - | positive | - |
HMDB0001431_ms_ms_1576 | qTof | Quattro_QQQ | - | - | - | positive | - |
OUF00435 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010024 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |