MoNA MS database records for Trans-4-hydroxyproline
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
BAF_UVA_POS000109 | - | - | - | - | - | - | |
BAF_UVA_POS000110 | - | - | - | - | - | - | |
BAF_UVA_POS000111 | - | - | - | - | - | - | |
BAF_UVA_POS000112 | - | - | - | - | - | - | |
BAF_UVA_POS000113 | - | - | - | - | - | - | |
BAF_UVA_POS000805 | - | - | - | - | - | - | |
CCMSLIB00000577944 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000577959 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578181 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000578192 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005463976 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463977 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005464036 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464037 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005464039 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464105 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720386 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720677 | qTof | - | - | - | [M-H]- | negative | MS2 |
EMBL-MCF_spec109977 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec38061 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec38141 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
FiehnHILIC000424 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001996 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002755 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | Negative | MS2 |
FiehnLib000238 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000239 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000240 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
GLS00047 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
HMDB0000725_c_ms_1160 | GCMS-2010 Plus, Shimadzu | GC-MS | - | - | - | - | - |
HMDB0000725_c_ms_1212 | GCMS-2010 Plus, Shimadzu | GC-MS | - | - | - | - | - |
HMDB0000725_ms_ms_1017 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
HMDB0000725_ms_ms_1018 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
HMDB0000725_ms_ms_1019 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
HMDB0036576_c_ms_1210 | GCMS-2010 Plus, Shimadzu | GC-MS | - | - | - | - | - |
HMDB0036576_ei_ms_1150 | GCMS-2010 Plus, Shimadzu | - | - | - | - | - | - |
HMDB0036576_ms_ms_1017 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | MS2 |
MoNA001775 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA001777 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA001778 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA001814 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA001816 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA001817 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA010585 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010586 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010587 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010588 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010589 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010590 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010842 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA010843 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA010844 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA010845 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA016724 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA017621 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA024215 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
MoNA024232 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA032018 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032019 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032020 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA033926 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034816 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035957 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA035960 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA035962 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036616 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036617 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036619 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA037131 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037437 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037835 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038530 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038728 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038741 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MT000035 | LTQ XL, Thermo Finnigan | LC-ESI-IT | ESI | 40 | [M+H]+ | positive | MS2 |
OUF00473 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PM000922 | API 2000 | QqQ | ESI | 20 | [M+H]+ | positive | MS2 |
PR010075 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR100208 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100613 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PS036201 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS036202 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS036203 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS036207 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PT103620 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT203620 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |