MoNA MS database records for Trigonelline
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
BAF_UVA_POS000069 | - | - | - | - | - | - | |
BAF_UVA_POS000070 | - | - | - | - | - | - | |
BAF_UVA_POS000071 | - | - | - | - | - | - | |
CCMSLIB00000578046 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00003142437 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464011 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464012 | Orbitrap | - | - | - | [2M+Na]+ | positive | MS2 |
CCMSLIB00005464013 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005720489 | qTof | - | - | - | [M+H]+ | positive | MS2 |
HMDB0000875_ei_ms_1938 | qTof | - | - | - | - | - | - |
HMDB0000875_ms_ms_1235 | qTof | Quattro_QQQ | - | - | - | positive | - |
HMDB0000875_ms_ms_1236 | qTof | Quattro_QQQ | - | - | - | positive | - |
HMDB0000875_ms_ms_1237 | qTof | Quattro_QQQ | - | - | - | positive | - |
KO004201 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO004202 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO004203 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO004204 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO004205 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
ML005201 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
MoNA002136 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA002137 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA002138 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA010447 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010448 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010449 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010450 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010451 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010452 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA011431 | Agilent 6550 iFunnel | Q-TOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA011432 | Agilent 6550 iFunnel | Q-TOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA011433 | Agilent 6550 iFunnel | Q-TOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA011434 | Agilent 6550 iFunnel | Q-TOF | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA016805 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA017576 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA023989 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA032303 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032304 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA032305 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036208 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036210 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036211 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA037241 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037959 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038618 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
PM018202 | QTOF Premier | Q-TOF | ESI | 15->55V | [M+H]+ | positive | MS2 |
PR100409 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100410 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M+H]+ | positive | MS2 |
PS102601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS102602 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS102603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PT110260 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT110263 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ006359 | Thermo Finnigan LTQ | Linear Ion Trap | - | - | M+H | positive | MS2 |
VF-NPL-LTQ006360 | Thermo Finnigan LTQ | Linear Ion Trap | - | - | M+H | positive | MS2-MS3 Composite |
VF-NPL-QEHF003226 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003227 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003228 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF003229 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003230 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003231 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |