MoNA MS database records for Daidzein
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
VF-NPL-QTOF007268 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007269 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007270 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Cl]- | negative | MS2 |
CCMSLIB00000078891 | qTof | - | - | - | [M-H]- | negative | MS2 |
FiehnHILIC001140 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC002657 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
LU093751 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
LU093752 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
LU093753 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
LU093754 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M-H]- | negative | MS2 |
LU093755 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
LU093756 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
MoNA003269 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | Electrospray Ionization (ESI) | Stepped (NCE 20-30-40%) | [M-H]- | negative | MS2 |
PB002425 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M-H]- | negative | MS2 |
PB002426 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M-H]- | negative | MS2 |
PB002427 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
PB002428 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M-H]- | negative | MS2 |
PR040007 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M-H]- | negative | MS2 |
PR040008 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
PR100637 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100638 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M-H]- | negative | MS2 |
PR309180 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M-H]- | negative | MS2 |
PR309181 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M-H]- | negative | MS2 |
PT203970 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT203973 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M-H]- | negative | MS2 |
RIKENPlaSMA006284 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006291 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006298 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006305 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006311 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006318 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006324 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006331 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006338 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006345 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006352 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006359 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RP018111 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP018112 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
RP018113 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
SM882851 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF416351 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF416352 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M-H]- | negative | MS2 |
UF416353 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF416354 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF423951 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
UF423952 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M-H]- | negative | MS2 |
UF423953 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M-H]- | negative | MS2 |
UF423954 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M-H]- | negative | MS2 |
VF-NPL-QEHF013303 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013304 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013305 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QTOF001349 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001350 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001351 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF003547 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003548 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003549 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007274 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007275 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007276 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
AU287401 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU287402 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU287403 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU287404 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU287405 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU287406 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 20-30 eV | [M+H]+ | positive | MS2 |
CCMSLIB00000078314 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000078858 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000847779 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
FFF00070 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00071 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00072 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00073 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00074 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00075 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00076 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS1 |
FiehnHILIC000296 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001867 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
LU093701 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU093702 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU093703 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU093704 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU093705 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M+H]+ | positive | MS2 |
LU093706 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M+H]+ | positive | MS2 |
NA000031 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 160 % (nominal) | [M+H]+ | positive | MS2 |
NA000032 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 115 % (nominal) | [M+H]+ | positive | MS2 |
NA000033 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 170 % (nominal) | [M+H]+ | positive | MS2 |
NA000034 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 115 % (nominal) | [M+H]+ | positive | MS2 |
NA000035 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 180 % (nominal) | [M+H]+ | positive | MS2 |
NA002496 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10% (nominal) | [M+H]+ | positive | MS2 |
NA002497 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15% (nominal) | [M+H]+ | positive | MS2 |
NA002498 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20% (nominal) | [M+H]+ | positive | MS2 |
NA002499 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25% (nominal) | [M+H]+ | positive | MS2 |
NA002500 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30% (nominal) | [M+H]+ | positive | MS2 |
NA002889 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35% (nominal) | [M+H]+ | positive | MS2 |
NA002890 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40% (nominal) | [M+H]+ | positive | MS2 |
NA002891 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45% (nominal) | [M+H]+ | positive | MS2 |
NA002892 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50% (nominal) | [M+H]+ | positive | MS2 |
NA002893 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55% (nominal) | [M+H]+ | positive | MS2 |
NA003264 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60% (nominal) | [M+H]+ | positive | MS2 |
NA003265 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65% (nominal) | [M+H]+ | positive | MS2 |
NA003266 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70% (nominal) | [M+H]+ | positive | MS2 |
NA003267 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75% (nominal) | [M+H]+ | positive | MS2 |
NA003268 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80% (nominal) | [M+H]+ | positive | MS2 |
NA003634 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85% (nominal) | [M+H]+ | positive | MS2 |
NA003635 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90% (nominal) | [M+H]+ | positive | MS2 |
NA003636 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 95% (nominal) | [M+H]+ | positive | MS2 |
NA003637 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100% (nominal) | [M+H]+ | positive | MS2 |
NA003638 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105% (nominal) | [M+H]+ | positive | MS2 |
PB000821 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB000841 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB000842 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB000861 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M+H]+ | positive | MS2 |
PM013601 | QTRAP | QqQ | ESI | 27% | [M+H]+ | positive | MS2 |
PM015808 | TSQ | QqQ | ESI | 30V | [M+H]+ | positive | MS2 |
PR020020 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 5.0 V | [M+H]+ | positive | MS1 |
PR040009 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PR040010 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M+H]+ | positive | MS2 |
PR100225 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR310855 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
PS039701 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS039702 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS039703 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS039704 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PT103970 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
RIKENPlaSMA002625 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002631 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002637 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002643 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002649 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002655 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002661 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002667 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002673 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002679 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002685 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002691 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RP018101 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP018102 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP018103 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
SM882802 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416301 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF416302 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF416303 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416304 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF423901 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF423902 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF423903 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF423904 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013306 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013307 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013308 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001352 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001353 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001354 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003550 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003551 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003552 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007277 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007278 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007279 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000391 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000392 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-LTQ003699 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ003700 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-LTQ003701 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ003702 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS2 Composite |
VF-NPL-QTOF003544 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF003545 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF003546 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007271 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007272 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007273 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
FiehnLib000799 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0003312_c_ms_2166 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0003312_ms_ms_2236 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0003312_ms_ms_2237 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0003312_ms_ms_2238 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0003312_ms_ms_285596 | Leco Pegasus IV | ESI-TOF | - | - | - | negative | - |
HMDB0003312_ms_ms_285597 | Leco Pegasus IV | ESI-TOF | - | - | - | negative | - |
MetaboBASE0043 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
MetaboBASE0044 | impact HD | LC-ESI-TOF | ESI | 50 | - | negative | MS2 |
OUF00155 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |