Massbank MS database records for Melatonin
| Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|
| MSBNK-Antwerp_Univ-METOX_P100502_F638 | Agilent 6530 QTOF | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102301 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 15 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102302 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 20 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102303 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 25 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102304 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 30 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102305 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 40 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102306 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 50 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102307 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 60 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102308 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 70 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EQ01102309 | Exploris 240 Thermo Scientific | LC-ESI-QFT | 80 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO001407 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Keio_Univ-KO001408 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Keio_Univ-KO001409 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Keio_Univ-KO001410 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Keio_Univ-KO001411 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Keio_Univ-KO003432 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO003433 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO003434 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO003435 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO003436 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO009065 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.6 | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Keio_Univ-KO009066 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.60/0.65 | [M+H]+ | POSITIVE | MS3 |
| MSBNK-RIKEN_ReSpect-PS126301 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
| MSBNK-RIKEN_ReSpect-PS126302 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
| MSBNK-RIKEN_ReSpect-PS126303 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
| MSBNK-RIKEN_ReSpect-PS126304 | TQD, Waters | LC-ESI-QQ | 40 | - | POSITIVE | MS2 |
| MSBNK-RIKEN_ReSpect-PS126305 | TQD, Waters | LC-ESI-QQ | 50 | - | POSITIVE | MS2 |
| MSBNK-Washington_State_Univ-BML00698 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 10 ev | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Washington_State_Univ-BML00707 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 20 ev | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Washington_State_Univ-BML00716 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 40 ev | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Washington_State_Univ-BML00724 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 10 ev | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Washington_State_Univ-BML00731 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 20 ev | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Washington_State_Univ-BML00738 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 40 ev | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Washington_State_Univ-BML81675 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | POSITIVE | MS |
| MSBNK-Washington_State_Univ-BML81676 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | NEGATIVE | MS |
| MSBNK-Washington_State_Univ-BML81677 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | POSITIVE | MS |
| MSBNK-Washington_State_Univ-BML81678 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | NEGATIVE | MS |