Return to study ST000045 main page
MB Sample ID: SA001935
Local Sample ID: | Group5C |
Subject ID: | SU000063 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Species Group: | Human |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN000072 | AN000073 | AN000074 | AN000075 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | HILIC | Reversed phase | HILIC |
Chromatography system | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity |
Column | Waters high-strength silica (150 x 2.1mm,1.8um) | Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) | Waters high-strength silica (150 x 2.1mm,1.8um) | Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | TOF | TOF | TOF | TOF |
MS instrument name | Agilent 6220 TOF | Agilent 6220 TOF | Agilent 6220 TOF | Agilent 6220 TOF |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | Raw MS Intensities | Raw MS Intensities | Raw MS Intensities | Raw MS Intensities |
MS:
MS ID: | MS000053 |
Analysis ID: | AN000072 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | Positive-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min. |
Ion Mode: | POSITIVE |
MS ID: | MS000054 |
Analysis ID: | AN000073 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | Positive-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min. |
Ion Mode: | POSITIVE |
MS ID: | MS000055 |
Analysis ID: | AN000074 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | Negative-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min. |
Ion Mode: | NEGATIVE |
MS ID: | MS000056 |
Analysis ID: | AN000075 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | Negative-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min. |
Ion Mode: | NEGATIVE |