MB Sample ID: SA254482

Local Sample ID:WTFAST3
Subject ID:SU002622
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004155 AN004156
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system SHIMADZU UHPLC Nexera LC-30A SHIMADZU UHPLC Nexera LC-30A
Column Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Relative intensity Relative intensity

MS:

MS ID:MS003902
Analysis ID:AN004155
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:mass spectrometric analysis was performed using a Q Exactive mass spectrometer (Thermo Scientific). ESI source conditions were as follows: Heater Temp 300 °C, Sheath Gas Flow rate 45 arb, Aux Gas Flow Rate15 arb, Sweep Gas Flow Rate 1arb, Spray voltage 3.0KV, Capillary Temp 350 °C, S-Lens RF Level 50%, MS1scan ranges: 200-1800. The mass-charge ratio of lipid molecules and lipid fragments were obtained by collecting 10 fragment maps (MS 2scan, HCD) after each fullscan. The resolution of MS1 at M/Z 200 was 70,000 and that of MS2 at M/Z 200 was 17,500. LipidSearch was used for peak identification, peak extraction and lipid molecules identification (secondary identification). The main parameters were precursor tolerance: 5 ppm, Product Tolerance: 5 ppm, and Product Ion Threshold: 5%. The obtained data were subjected to quality control for subsequent data lipid difference analysis.
Ion Mode:POSITIVE
  
MS ID:MS003903
Analysis ID:AN004156
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:mass spectrometric analysis was performed using a Q Exactive mass spectrometer (Thermo Scientific). ESI source conditions were as follows: Heater Temp 300 °C, Sheath Gas Flow rate 45 arb, Aux Gas Flow Rate15 arb, Sweep Gas Flow Rate 1arb, Spray voltage 3.0KV, Capillary Temp 350 °C, S-Lens RF Level 50%, MS1scan ranges: 200-1800. The mass-charge ratio of lipid molecules and lipid fragments were obtained by collecting 10 fragment maps (MS 2scan, HCD) after each fullscan. The resolution of MS1 at M/Z 200 was 70,000 and that of MS2 at M/Z 200 was 17,500. LipidSearch was used for peak identification, peak extraction and lipid molecules identification (secondary identification). The main parameters were precursor tolerance: 5 ppm, Product Tolerance: 5 ppm, and Product Ion Threshold: 5%. The obtained data were subjected to quality control for subsequent data lipid difference analysis.
Ion Mode:NEGATIVE