Summary of Study ST001850
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001167. The data can be accessed directly via it's Project DOI: 10.21228/M8VM4C This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001850 |
Study Title | Unbiased LC-MS-based metabolomics analysis for both whole cell and mitochondria metabolites to gain an insight into the role of Tug1/PGC1 axis on metabolite profiles in podocytes |
Study Summary | unbiased LC-MS-based metabolomics analysis for both whole cell and mitochondria metabolites to gain an insight into the role of Tug1/PGC1 axis on metabolite profiles in podocytes |
Institute | University of Texas MD Anderson Cancer Center |
Last Name | Danesh |
First Name | Farhad |
Address | 1515 Holcombe Blvd, Houston ,TX77030 |
fdanesh@mdanderson.org | |
Phone | 7135634498 |
Submit Date | 2021-06-25 |
Num Groups | 3 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | LC-MS |
Release Date | 2021-06-29 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002997 | AN002998 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Ion exchange | HILIC |
Chromatography system | Thermo Dionex ICS-5000+ | Thermo Vanquish |
Column | Dionex IonPac AS11 | Waters XBridge Amide (100 x 4.6mm,3.5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Fusion Orbitrap | Thermo Fusion Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | AUC/ngDNA | AUC/ngDNA |
MS:
MS ID: | MS002786 |
Analysis ID: | AN002997 |
Instrument Name: | Thermo Fusion Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data were acquired using a Thermo Orbitrap Fusion Tribrid Mass Spectrometer under ESI negative ionization mode. Raw data files were imported to Thermo Trace Finder software for final analysis. The relative abundance of each metabolite was normalized by DNA concentrations. |
Ion Mode: | NEGATIVE |
MS ID: | MS002787 |
Analysis ID: | AN002998 |
Instrument Name: | Thermo Fusion Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data were acquired using a Thermo Orbitrap Fusion Tribrid Mass Spectrometer under ESI positive ionization mode at a resolution of 240,000.Raw data files were imported to Thermo Trace Finder software for final analysis. The relative abundance of each metabolite was normalized by DNA concentrations. |
Ion Mode: | POSITIVE |