Summary of Study ST002053
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001297. The data can be accessed directly via it's Project DOI: 10.21228/M82H7B This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002053 |
Study Title | Resistance to NaFAc of in vitro maturated Toxoplasma gondii bradyzoites in human myotubes. |
Study Summary | The apicomplexan parasite Toxoplasma gondii forms bradyzoite-containing tissue cysts that cause chronic and drug-tolerant infections. Here, we developed a human myotube-based in vitro culture model of functionally mature tissue cysts. In contrast to fast replicating tachyzoite forms of T. gondii these tissue cysts tolerate exposure to the aconitase inhibitor sodium fluoroacetate. These data characterize bradyzoites and tachyzoites treated with NaFAc. |
Institute | Robert Koch-Institute |
Last Name | Blume |
First Name | Martin |
Address | Seestr. 10, Berlin, Berlin, 13353, Germany |
blumem@rki.de | |
Phone | +49 30 18754 2572 |
Submit Date | 2022-01-07 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-02-28 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003343 |
---|---|
Analysis type | MS |
Chromatography type | HILIC |
Chromatography system | Thermo Vanquish |
Column | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive Plus Orbitrap |
Ion Mode | UNSPECIFIED |
Units | counts |
MS:
MS ID: | MS003112 |
Analysis ID: | AN003343 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The injection order of the samples was randomized, blanks and PBQCs were injected periodically. The samples were analyzed on a Q-Exactive Plus mass spectrometer (Thermo Fisher Scientific) via 70k MS1 scans, with intermittent 35k data-dependent 35k MS2 scans in positive and negative mode separately.XCalibur 4.2.47 software and Compound Discoverer 3.1 software (Thermo Fisher Scientific) was used for recording and used for peak detection, combination of adducts and compound annotation, respectively. Metabolite identifications were based on either retention time and accurate mass match to an in-house library of 160 authentic standards, or by matching accurate mass and MS2 fragments to m/z cloud database (mirrored offline in m/z vault v 2.1.22.15 in May 2020) (Thermo Fisher Scientific). Data were exported to Excel for grouping, combination of datasets from positive and negative ionization runs and blank subtraction.. |
Ion Mode: | UNSPECIFIED |