Return to study ST000040 main page

MB Sample ID: SA001769

Local Sample ID:Test_3P
Subject ID:SU000057
Subject Type:Invertebrate
Subject Species:Caenorhabditis elegans
Taxonomy ID:6239
Genotype Strain:N2
Age Or Age Range:Young Adult
Gender:Hermaphrodite
Species Group:Invertebrate

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000057
Subject Type:Invertebrate
Subject Species:Caenorhabditis elegans
Taxonomy ID:6239
Genotype Strain:N2
Age Or Age Range:Young Adult
Gender:Hermaphrodite
Species Group:Invertebrate

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Test_3PSA001769FL000591heat shockHeat shock
Test_3PSA001769FL000591endometabolomeMetabolome

Collection:

Collection ID:CO000040
Collection Summary:-
Sample Type:whole young adult C. elegans Heat shock | supernatant Heat shock | whole young adult C. elegans Control | supernatant Control
Collection Method:centrifugation | Filtration (0.2 micron) | centrifugation | Filtration (0.2 micron)
Volumeoramount Collected:225,000 worms | 10 mL worm water | 250,000 worms | 10 mL worm water

Treatment:

Treatment ID:TR000058
Treatment Summary:Heat Shock: Two successive synchronous generations of wild-type C. elegans (N2) were grown in S-complete buffer at 22C containing 5% 13C-labeled E. coli. Upon reaching the young adult stage, the population was washed from E. coli using standard procedures and was divided into four replicates. Each replicate was treated with a 30 min heat shock at 33 °C followed by incubation at 22C for 1.5 hours. Control: Two successive synchronous generations of wild-type C. elegans (N2) were grown in S-complete buffer at 22C containing 95% 13C-labeled E. coli. Upon reaching the young adult stage, the population was washed from E. coli using standard procedures.
Treatment:Abiotic
Treatment Dose:30C | 22C
Treatment Doseduration:30C for 30 minutes; 1.5 hours at 22 C before harvest | 22C for 30 minutes; 1.5 hours at 22 C before harvest
Animal Acclimation Duration:-

Sample Preparation:

Sampleprep ID:SP000053
Sampleprep Summary:Supernatant (endometabolome) was separated from worm pellets (exometabolome) by centrifugation. The supernatant was filtered, lyophilized, and resuspended in 100 μL of LC-MS grade H2O. Worm pellet (endometabolome)was separated from supernatant (exometabolome) by centrifugation. The worm pellets were homogenized using a Biospec Mini-Beadbeater-8 in 80% methanol, dried under nitrogen and resuspended in 100 μL of LC-MS grade H2O.
Processing Method:filtration with 0.2 micron nitrocellulose, frozen at -80C, lyophilized and resuspended in 100 μL of LC-MS grade H2O. homogenization with Biospec Mini-Beadbeater-8 in 80% methanol, dried under nitrogen and resuspended in 100 μL of LC-MS grade H2O.

Combined analysis:

Analysis ID AN000060 AN000061
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Accela 1250 Thermo Accela 1250
Column Thermo Scientific Gold aQ Thermo Scientific Gold aQ
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak area Peak area

Chromatography:

Chromatography ID:CH000041
Chromatography Summary:Three microliters of each sample were injected onto a Thermo Scientific Gold aQ (150 × 2.1 mm, 1.9 μm) column using a column temperature of 40 °C and a flow rate of 600 μL/min with a gradient of solvent A (0.1% formic acid in water) and solvent B (0.1% formic acid in acetonitrile) from 100% solvent A for 1 min followed by a linear gradient to 20% B in 6 min, a linear gradient to 60% B in 2 min, a linear gradient to 95% B in 4 min, held for 2 min, and a 3.5 min return to the starting composition. The inlet to the Orbitrap was held at a temperature of 320 °C, and the S-lens RF Level was set to 35%. The FR resolution was set to 70 000 at m/z 200. The accuracy achieved was routinely less than 1.5 ppm, externally calibrated.
Instrument Name:Thermo Accela 1250
Column Name:Thermo Scientific Gold aQ
Column Temperature:40 °C
Flow Gradient:A (0.1% formic acid in water) and solvent B (0.1% formic acid in acetonitrile) from 100% solvent A for 1 min followed by a linear gradient to 20% B in 6 min, a linear gradient to 60% B in 2 min, a linear gradient to 95% B in 4 min, held for 2 min, and a 3.5 min return to the starting composition
Sample Injection:3 ?L
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Analytical Time:18.5 min
Chromatography Type:Reversed phase

MS:

MS ID:MS000041
Analysis ID:AN000060
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were analyzed using a mass range of m/z 70-800 in positive and negative ionization mode, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with an Open Accela autosampler and an Accela 1250 pump (San Jose, CA). The Q-Exactive was equipped with a heated electrospray ionization (HESI) source, which operated at a spray temperature of 500 °C, a spray voltage of 3 kV, and sheath and auxiliary gas flow rates of 60 and 10 arbitrary units, respectively. Features were extracted from the ms data using proprietary MATLAB IROA scripts. Ratios for each feature (heatshock/control) were calculated for each replicate. Ratios were normalized by setting the median log-fold change for each sample to zero
Ion Mode:POSITIVE
Ion Source Temperature:500 °C
Ion Spray Voltage:3 kV
Mass Accuracy:1.5 ppm
Scan Range Moverz:70-1000
  
MS ID:MS000042
Analysis ID:AN000061
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were analyzed using a mass range of m/z 70-800 in positive and negative ionization mode, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with an Open Accela autosampler and an Accela 1250 pump (San Jose, CA). The Q-Exactive was equipped with a heated electrospray ionization (HESI) source, which operated at a spray temperature of 500 °C, a spray voltage of 3 kV, and sheath and auxiliary gas flow rates of 60 and 10 arbitrary units, respectively. Features were extracted from the ms data using proprietary MATLAB IROA scripts. Ratios for each feature (heatshock/control) were calculated for each replicate. Ratios were normalized by setting the median log-fold change for each sample to zero
Ion Mode:NEGATIVE
Ion Source Temperature:500 °C
Ion Spray Voltage:3 kV
Mass Accuracy:1.5 ppm
Scan Range Moverz:70-1000
  logo