Collection Summary:Plasma was collected in EDTA tubes from individuals after an overnight fast using standard venipuncture procedures.
Sample Type:Plasma
Collection Location:standard venipuncture

Treatment:

Treatment ID:TR000065

Sample Preparation:

Sampleprep ID:SP000060
Sampleprep Summary:The metabolite extraction method was performed as described previously [PMID: 22415876] with minor modifications in the method. Plasma and CSF samples (100 µL) were thawed on ice at 4°C followed by deproteinization with methanol (1:4 ratio of plasma to methanol) and vortexed for 10 s, followed by incubation at â??20°C for 2 h. Prior to deproteinization, 4 µL of an internal standard solution of 13C6-Phenylalanine (247 ng/µL) was added to each plasma, CSF, and quality control (QC) samples to monitor the recovery of extracted metabolites. The samples were centrifuged at 18000 g for 20 min at 4°C. The supernatants were lyophilized (Savant, Holbrook, NY) and stored at â??20°C prior to analysis. The samples were reconstituted in running buffer and analyzed within 24 hrs.

Combined analysis:

Analysis ID AN000076 AN000077 AN000078 AN000079
Analysis type MS MS MS MS
Chromatography type Reversed phase HILIC Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type TOF TOF TOF TOF
MS instrument name Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units Raw MS Intensities Raw MS Intensities Raw MS Intensities Raw MS Intensities

Chromatography:

Chromatography ID:CH000049
Chromatography Summary:C18
Chromatography Comments:Metabolite separation in plasma and CSF was achieved using an Acquity UPLC system (Waters, Milford, MA) with both hydrophilic interaction chromatography (HILIC) (ethylene-bridged hybrid 2.1150 mm, 1.7 mm; Waters) and reversed-phase liquid chromatography C18 (RPLC) (high-strength silica 2.1150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. The injection volume of each sample was 5 L and column was maintained at 50C. Each sample was injected and analyzed in duplicate.
Instrument Name:Waters Acquity
Column Name:Waters high-strength silica (150 x 2.1mm,1.8um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH000050
Chromatography Summary:HILIC
Chromatography Comments:Metabolite separation in plasma and CSF was achieved using an Acquity UPLC system (Waters, Milford, MA) with both hydrophilic interaction chromatography (HILIC) (ethylene-bridged hybrid 2.1150 mm, 1.7 mm; Waters) and reversed-phase liquid chromatography C18 (RPLC) (high-strength silica 2.1150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. The injection volume of each sample was 5 L and column was maintained at 50C. Each sample was injected and analyzed in duplicate.
Instrument Name:Waters Acquity
Column Name:Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
Chromatography Type:HILIC

MS:

MS ID:MS000057
Analysis ID:AN000076
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Positive-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000058
Analysis ID:AN000077
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Positive-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000059
Analysis ID:AN000078
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Negative-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE
  
MS ID:MS000060
Analysis ID:AN000079
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Negative-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE