Return to study ST000346 main page

MB Sample ID: SA015303

Local Sample ID:BAL_Normal_6880_015
Subject ID:SU000366
Subject Type:Animal
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000366
Subject Type:Animal
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
BAL_Normal_6880_015SA015303FL003397No AsthmaCondition

Collection:

Collection ID:CO000360
Collection Summary:50ml of hospital grade sterile saline was instilled into the lungs of human volunteers. As much liquid as possible is then gently suctioned out. The sample is then centrifuged to remove cellular material and debris, and supernatant collected and frozen at -80C
Collection Protocol Filename:StudyDesign-GerardKaiko10202015.pdf
Sample Type:Bronchoalveolar lavage supernatant

Treatment:

Treatment ID:TR000380
Treatment Summary:The 3 groups are as follows: 1. Healthy controls (5) 2. Subjects with mild asthma (5) 3. Subjects with severe asthma (5)
Treatment Protocol Filename:StudyDesign-GerardKaiko10202015.pdf

Sample Preparation:

Sampleprep ID:SP000373
Sampleprep Summary:None

Combined analysis:

Analysis ID AN000561 AN000562
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 6530 Agilent 6550
Column Waters Acquity CSH C18 (100 x 2.1mm,1.7um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak height Peak height

Chromatography:

Chromatography ID:CH000398
Chromatography Summary:UPLC
Methods Filename:Data_Dictionary_Fiehn_laboratory_CSH_QTOF_lipidomics_05-29-2014.pdf
Instrument Name:Agilent 6530
Column Name:Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
Column Pressure:450-850 bar
Column Temperature:65 C
Flow Gradient:15% B to 99% B
Flow Rate:0.6 mL/min
Sample Injection:1.67 uL
Solvent A:60% acetonitrile/40% water; 10mM formic acid; 10mM ammonium formate
Solvent B:90% isopropanol/10% acetonitrile; 10mM formic acid; 10mM ammonium formate
Analytical Time:13 min
Capillary Voltage:3500
Time Program:15 min
Weak Wash Solvent Name:Isopropanol
Weak Wash Volume:5 seconds
Strong Wash Solvent Name:Same
Target Sample Temperature:Autosampler temp 4 C
Randomization Order:Excel
Chromatography Type:Reversed phase
  
Chromatography ID:CH000399
Chromatography Summary:UPLC
Methods Filename:Data_Dictionary_Fiehn_laboratory_CSH_QTOF_lipidomics_05-29-2014.pdf
Instrument Name:Agilent 6550
Column Name:Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
Column Pressure:450-850 bar
Column Temperature:65 C
Flow Gradient:15% B to 99% B
Flow Rate:0.6 mL/min
Sample Injection:5.0 uL
Solvent A:60% acetonitrile/40% water; 10mM formic acid; 10mM ammonium formate
Solvent B:90% isopropanol/10% acetonitrile; 10mM formic acid; 10mM ammonium formate
Analytical Time:13 min
Capillary Voltage:3500
Time Program:15 min
Weak Wash Solvent Name:Isopropanol
Weak Wash Volume:5 seconds
Strong Wash Solvent Name:Same
Target Sample Temperature:Autosampler temp 4 C
Randomization Order:Excel
Chromatography Type:Reversed phase

MS:

MS ID:MS000497
Analysis ID:AN000561
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Lipidomics runs are MS1 data; Identifications made from pooled MS/MS runs Lipidomics runs are performed in negative and positve mode (two filenames)
Ion Mode:POSITIVE
Capillary Voltage:3500
Collision Gas:Nitrogen
Dry Gas Flow:8 l/min
Dry Gas Temp:325
Fragment Voltage:120
Fragmentation Method:Auto MS/MS
Ion Source Temperature:200
Ion Spray Voltage:1000
Ionization:Neg
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 l/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  
MS ID:MS000498
Analysis ID:AN000562
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Lipidomics runs are MS1 data; Identifications made from pooled MS/MS runs Lipidomics runs are performed in negative and positve mode (two filenames)
Ion Mode:NEGATIVE
Capillary Voltage:3500
Collision Gas:Nitrogen
Dry Gas Flow:13 l/min
Dry Gas Temp:325
Fragment Voltage:175
Fragmentation Method:Auto MS/MS
Ion Source Temperature:200
Ion Spray Voltage:1000
Ionization:Neg
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 l/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  logo