Return to study ST000367 main page

MB Sample ID: SA016518

Local Sample ID:02_UK49
Subject ID:SU000388
Subject Type:Animal
Subject Species:Homo sapiens
Taxonomy ID:9606
Subject Comments:tissue_slice
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000388
Subject Type:Animal
Subject Species:Homo sapiens
Taxonomy ID:9606
Subject Comments:tissue_slice
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
02_UK49SA016518FL00371713C6GlcTreatment
02_UK49SA016518FL003717tumorTissue type

Collection:

Collection ID:CO000382
Collection Summary:2 methods were used: Precellys homogenization (Precellys_homogenization_SOP-2015-04-09.pdf, measurements: IC-FTMS1) and Retsch homogenization (protocol: Retsch_homogenization_SOP-2015-09-27.pdf, measurements: IC-FTMS2)
Collection Protocol Filename:Precellys_homogenization_SOP-2015-04-09.pdf
Retsch_homogenization_SOP-2015-09-27.pdf
Collection Protocol Comments:Precellys_homogenization_SOP-2015-04-09.pdf (IC-FTMS1), Retsch_homogenization_SOP-2015-09-27.pdf (IC-FTMS2)
Sample Type:Lung

Treatment:

Treatment ID:TR000402
Treatment Summary:none
Treatment Protocol Filename:SIRM_ex_vivo_tissue_slices_protocol__Bio-protocol_6_e1730__2016.pdf
Treatment Protocol Comments:ex vivo tissue slice experiment with isotopic labeling.

Sample Preparation:

Sampleprep ID:SP000395
Sampleprep Summary:Preparation of polar samples for GCMS, NMR, and IC-FTMS; Protein extraction and quantification
Sampleprep Protocol Filename:Extract_Polar_Lipid_Prot_Fan.pdf
Extract_Protein_Quant_Fan.pdf

Combined analysis:

Analysis ID AN000600 AN000601
Analysis type MS MS
Chromatography type Ion Chromatography Ion Chromatography
Chromatography system Thermo Dionex ICS-5000+ Thermo Dionex ICS-5000+
Column Unspecified Unspecified
MS Type ESI ESI
MS instrument type FT-ICR-MS FT-ICR-MS
MS instrument name Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap
Ion Mode NEGATIVE NEGATIVE
Units normalized corrected peak area normalized corrected peak area

Chromatography:

Chromatography ID:CH000427
Instrument Name:Thermo Dionex ICS-5000+
Column Name:Unspecified
Chromatography Type:Ion Chromatography

MS:

MS ID:MS000533
Analysis ID:AN000600
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:FT-ICR-MS
MS Type:ESI
MS Comments:IC-FTMS1: Data were adjusted as follows: 1)Get raw XIC peak areas from TF33 -> 2)correct for protein content by adjusting the signals according by wet weight -> 3) correct for NA abundance. Some compounds were assigned using a sperate standard run, others were assigned because they were the only or the highest peak in the extracted ion chromatogram. (XIC).
Ion Mode:NEGATIVE
  
MS ID:MS000534
Analysis ID:AN000601
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:FT-ICR-MS
MS Type:ESI
MS Comments:IC-FTMS2: Data were adjusted as follows: 1)Get raw XIC peak areas from TF33 -> 2)correct for protein content by reconstituting the volumes according to tissue wet weight -> 3) correct for NA abundance. Some compounds were assigned using a sperate standard run, others were assigned because they were the only or the highest peak in the extracted ion chromatogram. (XIC).