Return to study ST000389 main page

MB Sample ID: SA018315

Local Sample ID:131009dlvsa39_1
Subject ID:SU000410
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:53-81
Gender:Male/Female
Human Smoking Status:Former/Current
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000410
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:53-81
Gender:Male/Female
Human Smoking Status:Former/Current
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
131009dlvsa39_1SA018315FL004966FormerSmoking Status
131009dlvsa39_1SA018315FL004966MaleGender
131009dlvsa39_1SA018315FL004966YesEmphysema/COPD
131009dlvsa39_1SA018315FL004966CancerGroup

Collection:

Collection ID:CO000404
Collection Summary:Blood samples were collected from all patients enrolled in the protocol before diagnosis (>6 months prior to surgery, pre-diagnostic). Additional blood samples were collected from some of the lung cancer patients, at-diagnosis (at diagnosis) and post-treatment (after surgery). All but one patient had their “at-diagnosis” sample collected before surgery, usually within days prior to surgery, likely on their pre-operation visit. Surgery was usually performed within 1–3 months of diagnosis. Diagnosis was made by biopsy and/or surgery with all tissue diagnoses confirmed by pathology.
Sample Type:Blood
Blood Serum Or Plasma:Serum

Treatment:

Treatment ID:TR000424
Treatment Summary:The NYU Lung Cancer Biomarker Center performs low-dose CT-scan screening for high-risk smokers as part of the National Cancer Institute’s Early Detection Research Network Program (EDRN). Lung cancer cases for this study were confirmed by pathology (Table 1). Patients with benign nodules were those with stable nodules or ground glass opacity (GGO) over at least two year period with annual CT scans performed. Post-diagnosis samples were collected at least one month post-surgery. Selection of cases was performed by NYU and the blinded serum samples were sent to University of California, Davis Medical Center (UCDMC) for analysis. None of the study subjects had previous cancer or chemotherapy. All subjects had blood drawn by EDRN protocol, performed spirometry according to ATS guidelines,and answered questionnaires with smoking and occupational history.

Sample Preparation:

Sampleprep ID:SP000417
Sampleprep Summary:1. Switch on bath to pre-cool at –20°C (±2°C validity temperature range) 2. Gently rotate or aspirate the blood samples for about 10s to obtain a homogenised sample. 3. Aliquot 30μl of plasma sample to a 1.0 mL extraction solution. The extraction solution has to be prechilled using the ThermoElectron Neslab RTE 740 cooling bath set to -20°C. 4. Vortex the sample for about 10s and shake for 5 min at 4°C using the Orbital Mixing Chilling/Heating Plate. If you are using more than one sample, keep the rest of the sample on ice (chilled at <0°C with sodium chloride). 5. Centrifuge samples for 2min at 14000 rcf using the centrifuge Eppendorf 5415 D. 6. Aliquot two 450μL portions of the supernatant. One for analysis and one for a backup sample. Store the backup aliquot in -20°C freezer. 7. Evaporate one 450μL aliquots of the sample in the Labconco Centrivap cold trap concentrator to complete dryness. 8. The dried aliquot is then re-suspended with 450 μL 50% acetonitrile (degassed as given above). 9. Centrifuged for 2 min at 14000 rcf using the centrifuge Eppendorf 5415. 10. Remove supernatant to a new Eppendorf tube. 11. Evaporate the supernatant to dryness in the Labconco Centrivap cold trap concentrator. 12. Submit to derivatization.
Sampleprep Protocol Filename:SOP blood-GCTOF-11082012.pdf

Combined analysis:

Analysis ID AN000625
Analysis type MS
Chromatography type GC
Chromatography system Leco Pegasus III GC
Column Restek Corporation Rtx-5Sil MS
MS Type EI
MS instrument type GC-TOF
MS instrument name Leco Pegasus III GC TOF
Ion Mode POSITIVE
Units counts

Chromatography:

Chromatography ID:CH000450
Instrument Name:Leco Pegasus III GC
Column Name:Restek Corporation Rtx-5Sil MS
Column Pressure:7.7 PSI
Column Temperature:50-330C
Flow Rate:1 ml/min
Injection Temperature:50 C ramped to 250 C by 12 C/s
Sample Injection:0.5 uL
Transferline Temperature:230C
Washing Buffer:Ethyl Acetate
Sample Loop Size:30 m length x 0.25 mm internal diameter
Randomization Order:Excel generated
Chromatography Type:GC

MS:

MS ID:MS000558
Analysis ID:AN000625
Instrument Name:Leco Pegasus III GC TOF
Instrument Type:GC-TOF
MS Type:EI
Ion Mode:POSITIVE
Ion Source Temperature:250 C
Ionization:Pos
Ionization Energy:70 eV
Mass Accuracy:Nominal
Source Temperature:250 C
Scan Range Moverz:85-500 Da
Scanning Cycle:17 Hz
Scanning Range:85-500 Da
Skimmer Voltage:1850 V