MB Sample ID: SA022896

Local Sample ID:UCSF-01030
Subject ID:SU000473
Subject Type:Animal
Subject Species:Mus musculus
Taxonomy ID:10090
Species Group:Mammal

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000473
Subject Type:Animal
Subject Species:Mus musculus
Taxonomy ID:10090
Species Group:Mammal

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
UCSF-01030SA022896FL006459VehicleSample

Collection:

Collection ID:CO000467
Collection Summary:Mice were sacrificed under deep isoflurane anesthesia, blood was collected by cardiac puncture, clotted, and 100–200 μL serum was snap frozen in liquid nitrogen. The heart was dissected, the atria and great vessels were excised,and the ventricles were allowed to beat in cold PBS to clear blood.
Sample Type:Blood

Treatment:

Treatment ID:TR000487
Treatment Summary:N/A

Sample Preparation:

Sampleprep ID:SP000480
Sampleprep Summary:sample extract reconstituted in solvents containing a series of standards at fixed concentrations to ensure injection and chromatographic consistency. One aliquot was analyzed using acidic positive ion conditions, chromatographically optimized for more hydrophilic compounds. The extract was gradient eluted from a C18 column (Waters UPLC BEH C18-2.1 × 100 mm, 1.7 μm) using water and methanol, containing 0.05 % perfluoropentanoic acid (PFPA) and 0.1 % formic acid (FA). Another aliquot was also analyzed using acidic positive ion conditions,however it was chromatographically optimized for more hydrophobic compounds. In this method, the extract was gradient eluted from the same C18 column using methanol, acetonitrile, water, 0.05 % PFPA and 0.01 % FA and was operated at an overall higher organic content. Another aliquot was analyzed using basic negative ion optimized conditions using a separate dedicated C18 column. The basic extracts were gradient eluted from the column using methanol and water

Combined analysis:

Analysis ID AN000708
Analysis type MS
Chromatography type GC
Chromatography system Waters Acquity
Column Waters Acquity BEH C18 (100 x 2mm,1.7um)
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent 5975
Ion Mode POSITIVE
Units Peak values (scaled)

Chromatography:

Chromatography ID:CH000512
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Chromatography Type:GC

MS:

MS ID:MS000630
Analysis ID:AN000708
Instrument Name:Agilent 5975
Instrument Type:Single quadrupole
MS Type:EI
Ion Mode:POSITIVE