Return to study ST000575 main page

MB Sample ID: SA030399

Local Sample ID:PBS Ctl 7
Subject ID:SU000598
Subject Type:Animal
Subject Species:Mus musculus
Taxonomy ID:10090
Species Group:Mammal

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000598
Subject Type:Animal
Subject Species:Mus musculus
Taxonomy ID:10090
Species Group:Mammal

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
PBS Ctl 7SA030399FL007117Vehicle (PBS) Control TreatmentVehicle (PBS) Control Treatment

Collection:

Collection ID:CO000592
Collection Summary:Skeletal muscle (gastrocnemius) was harvested and flash frozen in a liquid nitrogen cooled biopress
Sample Type:Muscle

Treatment:

Treatment ID:TR000612
Treatment Summary:None

Sample Preparation:

Sampleprep ID:SP000605
Sampleprep Summary:The samples were crash deprotonized by methanol precipitation and spiked with D27-deuterated myristic acid (D27-C14:0) as an internal standard for retention-time locking and dried. The trimethylsilyl-D27-C14:0 standard retention time (RT) was set at 16.727 min. Reactive carbonyls were stabilized at 50C with methoxyamine hydrochloride in dry pyridine. Metabolites were made volatile with TMS groups using N-methyl-N-(trimethylsilyl) trifluoroacetamide or MSTFA with catalytic trimethylchlorosilane at 50C.

Combined analysis:

Analysis ID AN000885
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890N
Column Agilent DB5-MS (15m x 0.25mm,0.25um)
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent 5975
Ion Mode POSITIVE
Units Peak values (Log transformed)

Chromatography:

Chromatography ID:CH000628
Chromatography Summary:GC/MS methods follow previous studies using a 6890 N GC connected to a 5975 Inert single quadrupole MS (Agilent Technologies, Santa Clara, CA) (Bonikos et al. 1975; Fiehn 2008; Kind et al. 2009). The two wall-coated, open-tubular GC columns connected in series are both from J&W/Agilent (part 122äóñ5512), DB5-MS, 15 meters in length, 0.25 mm in diameter, with an 0.25-l m luminal film. Positive ions generated with conventional electron-ionization at 70 eV are scanned broadly from 600 to 50 m/z in the detector throughout the 45 min cycle time.
Instrument Name:Agilent 6890N
Column Name:Agilent DB5-MS (15m x 0.25mm,0.25um)
Chromatography Type:GC

MS:

MS ID:MS000787
Analysis ID:AN000885
Instrument Name:Agilent 5975
Instrument Type:Single quadrupole
MS Type:EI
Ion Mode:POSITIVE
  logo