Return to study ST000589 main page

MB Sample ID: SA031910

Local Sample ID:13-100C
Subject ID:SU000612
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:60
Gender:male
Human Race:Caucasian
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000612
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:60
Gender:male
Human Race:Caucasian
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
13-100CSA031910FL007201100 uLPlasma Volume Extracted

Collection:

Collection ID:CO000606
Collection Summary:Plasma from blood drawn intravenously
Sample Type:Blood
Collection Method:IV
Additives:EDTA
Blood Serum Or Plasma:Plasma

Treatment:

Treatment ID:TR000626
Treatment Summary:no treatment

Sample Preparation:

Sampleprep ID:SP000619
Sampleprep Summary:Protein precipitation and drying followed by derivatization via methoxyamine and MSTFA
Extraction Method:Protein precipitation
Sample Derivatization:18 mg/mL methoxyamine hydrochloride in pyridine for 30 min at 50°C, followed by trimethylsilylation with N-methyl-N- (trimethylsilyl)trifluoroacetamide (MSTFA) for 30 min at 50°C
Sample Spiking:retention-time-lock internal standard of perdeuterated myristic acid

Combined analysis:

Analysis ID AN000904
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890N
Column Agilent DB5-MS (15m x 0.25mm,0.25um)
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent 5975B
Ion Mode POSITIVE
Units Peak area (Log2 transformed)

Chromatography:

Chromatography ID:CH000642
Chromatography Summary:GC/MS methods follow previous studies using a 6890 N GC connected to a 5975B Inert single quadrupole MS (Agilent Technologies, Santa Clara, CA) (Bonikos et al. 1975; Fiehn 2008; Kind et al. 2009). The two wall-coated, open-tubular GC columns connected in series are both from J&W/Agilent (part 122–5512), DB5-MS, 15 meters in length, 0.25 mm in diameter, with an 0.25-l m luminal film. Positive ions generated with conventional electron-ionization at 70 eV are scanned broadly from 600 to 50 m/z in the detector throughout the 45 min cycle time.
Instrument Name:Agilent 6890N
Column Name:Agilent DB5-MS (15m x 0.25mm,0.25um)
Flow Rate:2.0 mL/min
Time Program:initial GC oven temperature of 60°C increased at 10°C/min to a final temperature of 325°C
Chromatography Type:GC

MS:

MS ID:MS000804
Analysis ID:AN000904
Instrument Name:Agilent 5975B
Instrument Type:Single quadrupole
MS Type:EI
Ion Mode:POSITIVE
  logo