MB Sample ID: SA042673

Local Sample ID:18323
Subject ID:SU000806
Subject Type:human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000806
Subject Type:human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
18323SA042673FL008912Case controlStatus
18323SA042673FL008912EARACE

Collection:

Collection ID:CO000800
Collection Summary:Clinically annotated ancestry verified serum samples from the National Cancer Institute.
Sample Type:Blood

Treatment:

Treatment ID:TR000820
Treatment Summary:NA

Sample Preparation:

Sampleprep ID:SP000813
Sampleprep Summary:Briefly, 10 μl of undiluted plasma sample from each patient or control individual was placed in individual wells of a 96 well plate provided by the manufacturer. Samples were dried at room temperature using a nitrogen evaporator drying unit for 30 mins. Following this, 20 μl of 5% phenylisothiocyanate (PITC) reagent was added to the dried plasma spots and incubated for 20 min at RT. The plate was again dried under the nitrogen evaporator for 60 mins. Next, 300 μl of 5 mM ammonium acetate in methanol was added to each well and the mixture was incubated on a shaker (450 rpm) for 30 mins. The plate was then centrifuged at 100 g for 2 min resulting in a volume of ~ 250 μl sample in the plate (labeled as Flow injection or FIA plate). 150 μl of the sample was subsequently transferred from the FIA plate into a second plate (termed LC-MS plate). In total, all the samples were analyzed in three batches, each containing one FIA and LC-MS plate, respectively. 150 μl HPLC grade water was added to the LC-MS plate to make up the volume to 300 ul. In parallel, 500 μl of mass spectrometry injection solvent (stock solution provided by Biocrates was diluted in methanol) was added to the FIA plate. The LC-MS plate was analyzed using Multiple Reaction Monitoring post LC-MS fractionation. The FIA plate was stored at 4°C until the LC-MS plate was completed assayed.

Combined analysis:

Analysis ID AN001239
Analysis type MS
Chromatography type None (Direct infusion)
Chromatography system None
Column none
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name AB Sciex 6500 QTRAP LC-MS/MS
Ion Mode POSITIVE
Units uM

Chromatography:

Chromatography ID:CH000866
Chromatography Summary:Flow injection coupled to MRM was used to measure mono-unsaturated glycerophosphophocholines in samples in the FIA plate. For flow injection analysis, 20 μl of sample was injected directly into the MS at a flow rate of 30 μl/min in mobile phase.
Instrument Name:None
Column Name:none
Chromatography Type:None (Direct infusion)

MS:

MS ID:MS001133
Analysis ID:AN001239
Instrument Name:AB Sciex 6500 QTRAP LC-MS/MS
Instrument Type:Triple quadrupole
MS Type:ESI
Ion Mode:POSITIVE