Return to study ST000893 main page

MB Sample ID: SA052607

Local Sample ID:H35
Subject ID:SU000930
Subject Type:Animal
Subject Species:Mus musculus
Taxonomy ID:10090
Species Group:Mammal

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000930
Subject Type:Animal
Subject Species:Mus musculus
Taxonomy ID:10090
Species Group:Mammal

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
H35SA052607FL009985PBS CtlTreatment

Collection:

Collection ID:CO000924
Collection Summary:Cardiac (LV) tissue was harvested and immediately flash frozen in a liquid nitrogen cooled biopress.
Sample Type:Muscle

Treatment:

Treatment ID:TR000944
Treatment Summary:Fraction of cardiac tissue weighed (~25-50 mg wet weight), then the finely cut up tissue quickly added to fresh pre-made buffer (50 % acetyl-nitrile, 50 % water, 0.3% formic acid) at a standard concentration of 25 mg/475 mcl buffer then fully homogenized on ice for ~20 s and placed on dry ice/stored at - 80C.

Sample Preparation:

Sampleprep ID:SP000937
Sampleprep Summary:The samples were crash deprotonized by methanol precipitation and spiked with D27-deuterated myristic acid (D27-C14:0) as an internal standard for retention-time locking and dried. The trimethylsilyl-D27-C14:0 standard retention time (RT) was set at 16.727 min. Reactive carbonyls were stabilized at 50C with methoxyamine hydrochloride in dry pyridine. Metabolites were made volatile with TMS groups using N-methyl-N-(trimethylsilyl) trifluoroacetamide or MSTFA with catalytic trimethylchlorosilane at 50C.

Combined analysis:

Analysis ID AN001455
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890N
Column Agilent DB5-MS (15m x 0.25mm,0.25um)
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent 5975
Ion Mode POSITIVE
Units Peak values (Log transformed)

Chromatography:

Chromatography ID:CH001022
Chromatography Summary:GC/MS methods follow previous studies using a 6890 N GC connected to a 5975 Inert single quadrupole MS (Agilent Technologies, Santa Clara, CA) (Bonikos et al. 1975; Fiehn 2008; Kind et al. 2009). The two wall-coated, open-tubular GC columns connected in series are both from J&W/Agilent, DB5-MS, 15 meters in length, 0.25 mm in diameter, with an 0.25-l m luminal film. Positive ions generated with conventional electron-ionization at 70 eV are scanned broadly from 600 to 50 m/z in the detector throughout the 45 min cycle time.
Instrument Name:Agilent 6890N
Column Name:Agilent DB5-MS (15m x 0.25mm,0.25um)
Chromatography Type:GC

MS:

MS ID:MS001343
Analysis ID:AN001455
Instrument Name:Agilent 5975
Instrument Type:Single quadrupole
MS Type:EI
Ion Mode:POSITIVE
  logo