Return to study ST000913 main page

MB Sample ID: SA053713

Local Sample ID:Lipkin075_posHILIC_DPCSF9627_092.d
Subject ID:SU000951
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000951
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Lipkin075_posHILIC_DPCSF9627_092.dSA053713FL010074MSDiagnosis
Lipkin075_posHILIC_DPCSF9627_092.dSA053713FL010074FEMALESex

Collection:

Collection ID:CO000945
Collection Summary:CSF samples obtained from lumbar punctures were retrieved from bio-repositories at Sierra Internal Medicine (SIM) and Wisconsin Viral Research Group (WVRG). These biobank specimens were collected over time and maintained at -80°C.
Sample Type:CSF

Treatment:

Treatment ID:TR000965
Treatment Summary:3 groups: 32 ME/CFS cases (11 men, 21 women) 59 comparator/control subjects (18 men, 41 women), including: 40 subjects with multiple sclerosis (MS) 19 subjects with non-infectious/non-inflammatory conditions (ND)

Sample Preparation:

Sampleprep ID:SP000958
Sampleprep Summary:1) Thaw each 100 μL CSF aliquot at room temperature (see Aliquoting TEDDY samples SOP). Once thawed (~10min) place CSF plasma samples on ice. 2) Add 225 μL cold “MeOH with QC mix” (see SOP “QC mix for LC-MS lipid analysis”). Keep MeOH on ice during extraction 3) Vortex each sample for 10s, keeping the rest on ice during all the extraction. 4) Add 750 μL of cold MTBE with 22:1 CE, keep MTBE on ice during extraction 5) Vortex for 10s 6) Shake for 6min at 4°C in the orbital mixer. 7) Add 188 μL room temperature LC/MS grade water. 8) Vortex for 20 s 9) Centrifuge for 2 min @ 14,000 rcf (12300 rpm) 10) Remove supernatant (upper phase) 11) Aliquot the remaining aqueous phase into two separate tubes 125 uL per tube, keeping one at -20°C for backup 12) Dry samples to complete dryness in the speed vacuum concentration system

Combined analysis:

Analysis ID AN001483
Analysis type MS
Chromatography type HILIC
Chromatography system Agilent 6530
Column Waters Acquity BEH C18 (100 x 2mm,1.7um)
MS Type ESI
MS instrument type QTOF
MS instrument name Agilent 6530 QTOF
Ion Mode POSITIVE
Units Counts

Chromatography:

Chromatography ID:CH001041
Instrument Name:Agilent 6530
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Column Pressure:200-700 bar
Column Temperature:40 C
Flow Gradient:0 min 100% (B), 0-2 min 100% (B), 2-7 min 70% (B), 7.7-9 min 40% (B), 9.5-10.25 min 30% (B), 10.25- 12.75 min 100% (B), 16.75 min 100% (B)
Flow Rate:0.4 mL/min
Injection Temperature:4 C
Internal Standard:See data dictionary
Retention Time:See data dictionary
Sample Injection:3 μL
Analytical Time:14 min
Capillary Voltage:4500 eV
Time Program:16.75 min
Weak Wash Solvent Name:1:1 ACN:H2O
Strong Wash Solvent Name:Same
Target Sample Temperature:Autosampler temp 4 C
Randomization Order:Excel generated
Chromatography Type:HILIC

MS:

MS ID:MS001367
Analysis ID:AN001483
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
Capillary Voltage:3500 eV
Collision Energy:45 eV
Collision Gas:Nitrogen
Dry Gas Flow:8L/min
Dry Gas Temp:325 C
Fragment Voltage:120 eV
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325 C
Ion Spray Voltage:1000
Ionization:Pos
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 L/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Resolution Setting:Extended Dyamic Range
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  logo