Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
40023454_2SA074295FL011438PLACEBOAspirin Dosage
40023454_2SA074295FL011438Colon Mucosal TissueSample.Matrix

Collection:

Collection ID:CO001129
Collection Summary:Fresh frozen normal colon mucosal tissue samples were collected from participants in the Aspirin/Folate Polyp Prevention Study [1, 2] at the year three (end of treatment) colonoscopy. After the endoscope was advanced to the cecum, biopsy specimens were obtained from the mid-ascending colon (5 cm above the ileocecal valve). Immediately after the biopsies were taken, they were removed from the forceps, placed into 1.8 ml freezer tubes and immersed in liquid nitrogen or a dry ice/ethanol slurry until storage in a -70C freezer. The specimens were shipped on dry ice from the clinical centers to the Dartmouth biorepository storage facility and subsequently to the metabolomics analysis lab at Emory University. In addition, a colon tissue reference was generated using normal colon tissue removed at surgery from an anonymous donor. References 1. Baron JA, Cole BF, Sandler RS, et al. A randomized trial of aspirin to prevent colorectal adenomas. The New England journal of medicine. 2003;348(10):891-9. 2. Cole BF, Baron JA, Sandler RS, et al. Folic acid for the prevention of colorectal adenomas: a randomized clinical trial. JAMA : the journal of the American Medical Association. 2007;297(21):2351-9.
Sample Type:Colon mucosal tissue
Storage Conditions:Described in summary

Treatment:

Treatment ID:TR001149
Treatment Summary:Samples were received frozen in aliquouts of <250uL. Prior to analysis, samples were thawed and prepared for HRM analysis using the standard protocols described in the Sample Preparation section.

Sample Preparation:

Sampleprep ID:SP001142
Sampleprep Summary:Samples were prepared for metabolomics analysis using established methods(Johnson et al. (2010). Analyst; Go et al. (2015). Tox Sci). Prior to analysis, plasma aliquots were removed from storage at -80 degrees C and thawed on ice. Each cryotube was then vortexed briefly to ensure homogeneity, and 50 microliters was transferred to a clean microfuge tube. Immediately after, the samples were treated with 200 microliters of ice-cold LC-MS grade acetonitrile (Sigma Aldrich) containing 5 microliters of internal standard solution with eight stable isotopic chemicals selected to cover a range of chemical properties. Following addition of acetonitrile, samples were homogenized for a few seconds using an Active Motif EpiShear probe sonicator and equilibrated for 30 min on ice, upon which precipitated proteins were removed by centrifuge (14,000 rpm at 4 degrees C for 10 min). The resulting supernatant (100 microliters) was removed, added to a low volume autosampler vial and maintained at 4 degrees C until analysis (<22 h).
Sampleprep Protocol ID:HRM_SP_082016_01
Sampleprep Protocol Filename:EmoryUniversity_HRM_sample_preparation_082016_01
Sampleprep Protocol Comments:Date effective: 30 July 2016
Extraction Method:2:1 acetonitrile: sample followed by vortexing and centrifugation

Combined analysis:

Analysis ID AN001776 AN001777
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters XBridge Amide (50 x 2.1mm,2.5um) Thermo Higgins C18 (50 x 2.1mm,3um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak area Peak area

Chromatography:

Chromatography ID:CH001255
Chromatography Summary:The HILIC column is operated parallel to reverse phase column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6-port switching valves. During operation of "HILIC separation method, the MS is operated in positive ion mode and 10" microliters of sample is injected onto the HILIC column while the reverse phase column is flushing with wash solution. Flow rate is maintained at 0.35 mL/min "until 1.5 min, increased to 0.4 mL/min at 4 min and held for 1 min. Solvent A is" "100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C" is 2% formic acid (v/v) in LC-MS grade water. Initial mobile phase conditions "are 22.5% A, 75% B, 2.5% C hold for 1.5 min, with linear gradient to 77.5% A," "20% B, 2.5% C at 4 min, hold for 1 min, resulting in a total analytical run time" "of 5 min. During the flushing phase (reverse phase analytical separation), the" "HILIC column is equilibrated with a wash solution of 77.5% A, 20% B, 2.5% C."
Methods ID:2% formic acid in LC-MS grade water
Methods Filename:20160920_posHILIC120kres5min_ESI_c18negwash.meth
Chromatography Comments:Triplicate injections for each chromatography mode
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters XBridge Amide (50 x 2.1mm,2.5um)
Column Temperature:60C
Flow Gradient:A= water, B= acetontrile, C= 2% formic acid in water; 22.5% A, 75% B, 2.5% C hold for 1.5 min, linear gradient to 77.5% A, 20% B, 2.5% C at 4 min, hold for 1 min
Flow Rate:0.35 mL/min for 1.5 min; linear increase to 0.4 mL/min at 4 min, hold for 1 min
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Sample Loop Size:15 uL
Sample Syringe Size:100 uL
Chromatography Type:HILIC
  
Chromatography ID:CH001256
Chromatography Summary:The C18 column is operated parallel to the HILIC column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6- port switching valves. During operation of the "C18 method, the MS is operated in negative ion mode and 10 μL of sample is" injected onto the C18 column while the HILIC column is flushing with wash "solution. Flow rate is maintained at 0.4 mL/min until 1.5 min, increased to 0.5" "mL/min at 2 min and held for 3 min. Solvent A is 100% LC-MS grade water, solvent" B is 100% LC-MS grade acetonitrile and solvent C is 10mM ammonium acetate in "LC-MS grade water. Initial mobile phase conditions are 60% A, 35% B, 5% C hold" "for 0.5 min, with linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3.5" "min, resulting in a total analytical run time of 5 min. During the flushing" "phase (HILIC analytical separation), the C18 column is equilibrated with a wash" "solution of 0% A, 95% B, 5% C until 2.5 min, followed by an equilibration" "solution of 60% A, 35% B, 5% C for 2.5 min."
Methods ID:10mM ammonium acetate in LC-MS grade water
Methods Filename:20160920_negC18120kres5min_ESI_HILICposwash.meth
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Thermo Higgins C18 (50 x 2.1mm,3um)
Column Temperature:60C
Flow Rate:0.4 mL/min for 1.5 min; linear increase to 0.5 mL/min at 2 min held for 3 min
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Sample Loop Size:15 uL
Sample Syringe Size:100 uL
Chromatography Type:Reversed phase

MS:

MS ID:MS001641
Analysis ID:AN001776
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:POSITIVE
Capillary Temperature:250C
Collision Gas:N2
Dry Gas Flow:45
Dry Gas Temp:150C
Mass Accuracy:< 3ppm
Spray Voltage:3500
Activation Parameter:5.00E+05
Activation Time:118ms
Interface Voltage:S-Lens RF level= 55
Resolution Setting:120000
Scanning Range:85-1275
Analysis Protocol File:EmoryUniversity_HRM_Fusion-MS_092017_v1.pdf
  
MS ID:MS001642
Analysis ID:AN001777
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Temperature:250C
Collision Gas:N2
Dry Gas Flow:45
Dry Gas Temp:150C
Mass Accuracy:< 3ppm
Spray Voltage:-4000
Activation Parameter:5.00E+05
Activation Time:118ms
Interface Voltage:S-Lens RF level= 55
Resolution Setting:120000
Scanning Range:85-1275
Analysis Protocol File:EmoryUniversity_HRM_Fusion-MS_092017_v1.pdf