MB Sample ID: SA080323

Local Sample ID:JHOP-05705
Subject ID:SU001222
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001222
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
JHOP-05705SA080323FL012310PlasmaSample
JHOP-05705SA080323FL012310Angiotensin IITREATMENT

Collection:

Collection ID:CO001216
Collection Summary:Plasma
Collection Protocol Filename:Sample_Collection-Feces_Pluznick.pdf
Sample Type:Blood (serum)

Treatment:

Treatment ID:TR001237
Treatment Summary:Six week old C57BL/6 conventional (mice with gut microbiota; conv, n=6) and germ-free (mice without gut microbiota; GF, n=6) mice were infused with angiotensin-II (AngII) for 4 weeks (400ng.kg-1.min-1; Alzet 1004). In parallel control groups, conv (n=6) and GF (n=6) mice received saline via minipumps.
Treatment Protocol Filename:Treatment_Protocol__Pluznick.pdf

Sample Preparation:

Sampleprep ID:SP001230
Sampleprep Summary:Samples were prepared using the automated MicroLab STARĀ® system from Hamilton Company. Several recovery standards were added prior to the first step in the extraction process for QC purposes. To remove protein, dissociate small molecules bound to protein or trapped in the precipitated protein matrix, and to recover chemically diverse metabolites, proteins were precipitated with methanol under vigorous shaking for 2 min (Glen Mills GenoGrinder 2000) followed by centrifugation. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVapĀ® (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis.

Combined analysis:

Analysis ID AN001915
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters Acquity
Column Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE
Units Peaks area

Chromatography:

Chromatography ID:CH001388
Methods Filename:Ultrahigh_Performance_LC_Method_Pluznick.pdf
Instrument Name:Waters Acquity
Column Name:Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
Chromatography Type:Reversed phase

MS:

MS ID:MS001771
Analysis ID:AN001915
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:None
Ion Mode:NEGATIVE