Return to study ST001193 main page

MB Sample ID: SA083011

Local Sample ID:C-1GVV8-CB-00_1
Subject ID:SU001260
Subject Type:Cord Blood
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:pediatric samples - 0 to 3 yrs

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001260
Subject Type:Cord Blood
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:pediatric samples - 0 to 3 yrs

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
C-1GVV8-CB-00_1SA083011FL012576Cord bloodPlasma

Collection:

Collection ID:CO001254
Collection Summary:Cord blood samples were collected from infant participants at birth. Cord blood collected in tubes containing EDTA were transferred to 1.8ml freezer tubes and stored in a -70 degrees C freezer. The samples were shipped on dry ice from the University of California Davis biorepository storage facility and subsequently to the metabolomics analysis lab at Emory University.
Sample Type:Cord Blood
Storage Conditions:Described in summary

Treatment:

Treatment ID:TR001275
Treatment Summary:Samples were received frozen in aliquouts of <250uL. Prior to analysis, samples were thawed and prepared for HRM analysis using the standard protocols described in the Sample Preparation section.

Sample Preparation:

Sampleprep ID:SP001268
Sampleprep Summary:Samples were prepared for metabolomics analysis using established methods(Johnson et al. (2010). Analyst; Go et al. (2015). Tox Sci). Prior to analysis, plasma aliquots were removed from storage at -80 degrees C and thawed on ice. Each cryotube was then vortexed briefly to ensure homogeneity, and 50 microliters was transferred to a clean microfuge tube. Immediately after, the plasma was treated with 100 microliters of ice-cold LC-MS grade acetonitrile (Sigma Aldrich) containing 2.5 microliters of internal standard solution with eight stable isotopic chemicals selected to cover a range of chemical properties. Following addition of acetonitrile, urine was equilibrated for 30 min on ice, upon which precipitated proteins were removed by centrifuge (14,000 rpm at 4 degrees C for 10 min). The resulting supernatant (100 microliters) was removed, added to a low volume autosampler vial and maintained at 4 degrees C until analysis (<22 h).
Sampleprep Protocol ID:HRM_SP_082016_01
Sampleprep Protocol Filename:EmoryUniversity_HRM_SP_082016_01.pdf
Sampleprep Protocol Comments:Date effective: 30 July 2016
Extraction Method:2:1 acetonitrile: sample followed by vortexing and centrifugation

Combined analysis:

Analysis ID AN001988 AN001989
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters XBridge BEH Amide XP HILIC (50 x 2.1mm x 2.5um) with Thermo Accucore HILIC guard Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH001436
Chromatography Summary:The HILIC column is operated parallel to reverse phase column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6-port switching valves. During operation of "HILIC separation method, the MS is operated in positive ion mode and 10" microliters of sample is injected onto the HILIC column while the reverse phase column is flushing with wash solution. Flow rate is maintained at 0.35 mL/min "until 1.5 min, increased to 0.4 mL/min at 4 min and held for 1 min. Solvent A is" "100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C" is 2% formic acid (v/v) in LC-MS grade water. Initial mobile phase conditions "are 22.5% A, 75% B, 2.5% C hold for 1.5 min, with linear gradient to 77.5% A," "20% B, 2.5% C at 4 min, hold for 1 min, resulting in a total analytical run time" "of 5 min. During the flushing phase (reverse phase analytical separation), the" "HILIC column is equilibrated with a wash solution of 77.5% A, 20% B, 2.5% C."
Methods ID:2% formic acid in LC-MS grade water
Methods Filename:20160920_posHILIC120kres5min_ESI_c18negwash.meth
Chromatography Comments:Triplicate injections for each chromatography mode
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters XBridge BEH Amide XP HILIC (50 x 2.1mm x 2.5um) with Thermo Accucore HILIC guard
Column Temperature:60C
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Sample Loop Size:15 uL
Sample Syringe Size:100 uL
Chromatography Type:HILIC
  
Chromatography ID:CH001437
Chromatography Summary:The C18 column is operated parallel to the HILIC column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6- port switching valves. During operation of the "C18 method, the MS is operated in negative ion mode and 10 μL of sample is" injected onto the C18 column while the HILIC column is flushing with wash "solution. Flow rate is maintained at 0.4 mL/min until 1.5 min, increased to 0.5" "mL/min at 2 min and held for 3 min. Solvent A is 100% LC-MS grade water, solvent" B is 100% LC-MS grade acetonitrile and solvent C is 10mM ammonium acetate in "LC-MS grade water. Initial mobile phase conditions are 60% A, 35% B, 5% C hold" "for 0.5 min, with linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3.5" "min, resulting in a total analytical run time of 5 min. During the flushing" "phase (HILIC analytical separation), the C18 column is equilibrated with a wash" "solution of 0% A, 95% B, 5% C until 2.5 min, followed by an equilibration" "solution of 60% A, 35% B, 5% C for 2.5 min."
Methods ID:10mM ammonium acetate in LC-MS grade water
Methods Filename:20160920_negC18120kres5min_ESI_HILICposwash.meth
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
Column Temperature:60C
Flow Rate:0.4 mL/min for 1.5 min; linear increase to 0.5 mL/min at 2 min held for 3 min
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Sample Loop Size:15 uL
Sample Syringe Size:100 uL
Chromatography Type:Reversed phase

MS:

MS ID:MS001841
Analysis ID:AN001988
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:NA
Ion Mode:POSITIVE
Capillary Temperature:250C
Collision Gas:N2
Dry Gas Flow:45
Dry Gas Temp:150C
Mass Accuracy:< 3ppm
Spray Voltage:3500
Activation Parameter:5.00E+05
Activation Time:118ms
Interface Voltage:S-Lens RF level= 55
Scanning Range:85-1275
Analysis Protocol File:EmoryUniversity_HRM_QEHF-MS_092017_v1.pdf
  
MS ID:MS001842
Analysis ID:AN001989
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:NA
Ion Mode:NEGATIVE
Capillary Temperature:250C
Collision Gas:N2
Dry Gas Flow:45
Dry Gas Temp:150C
Mass Accuracy:< 3ppm
Spray Voltage:-4000
Activation Parameter:5.00E+05
Activation Time:118ms
Interface Voltage:S-Lens RF level= 55
Scanning Range:85-1275
Analysis Protocol File:EmoryUniversity_HRM_QEHF-MS_092017_v1.pdf
  logo