Return to study ST001273 main page

MB Sample ID: SA093021

Local Sample ID:D14_7-
Subject ID:SU001345
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:C57BL/6J
Age Or Age Range:2 Months
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001345
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:C57BL/6J
Age Or Age Range:2 Months
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
D14_7-SA093021FL013315SonicationExposure
D14_7-SA093021FL013315Day FourteenDays Post Exposure

Collection:

Collection ID:CO001339
Collection Summary:Mice were exposed to a controlled sonication pulse and optic nerve samples were collected at 1 day, 7 days, and 14 days post sonication. Lipids were then extracted, resuspended in Chloroform:Methanol (1:1) and processed through untargeted liquid chromatography Q-Exactive Orbitrap tandem mass spectrometry (LC-MS/MS).
Sample Type:optic nerve

Treatment:

Treatment ID:TR001360
Treatment Summary:Mice were exposed to a 500msec sonication shock at the supraorbital rim that did not create any skull fractures nor cause death. Mice were sacrificed at 1 day, 7 days, or 14 days post exposure for lipid analysis of optic nerves.

Sample Preparation:

Sampleprep ID:SP001353
Sampleprep Summary:As described in collection

Combined analysis:

Analysis ID AN002113 AN002114
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Accela 600 Thermo Accela 600
Column Thermo Acclaim C18 (150 x 2.1mm,3m) Thermo Acclaim C18 (150 x 2.1mm,3m)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Main area Main area

Chromatography:

Chromatography ID:CH001547
Instrument Name:Thermo Accela 600
Column Name:Thermo Acclaim C18 (150 x 2.1mm,3m)
Chromatography Type:Reversed phase

MS:

MS ID:MS001968
Analysis ID:AN002113
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A Heated Electrospray Ionization Source (HESI) was operated at a spray voltage of 4.4kV, a HESI vaporization temperature of 275°C, a sheath gas pressure of 45 arbitrary units, and an auxillary gas flow of 15 arbitrary units. The ion transfer tube was kept at a temperature of 350°C. The scan range was set at 150-1500 m/z.
Ion Mode:POSITIVE
  
MS ID:MS001969
Analysis ID:AN002114
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A Heated Electrospray Ionization Source (HESI) was operated at a spray voltage of 4.4kV, a HESI vaporization temperature of 275°C, a sheath gas pressure of 45 arbitrary units, and an auxillary gas flow of 15 arbitrary units. The ion transfer tube was kept at a temperature of 350°C. The scan range was set at 150-1500 m/z.
Ion Mode:NEGATIVE