MB Sample ID: SA113187

Local Sample ID:L_K8D28
Subject ID:SU001463
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001463
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
L_K8D28SA113187FL01425028Day after birth

Collection:

Collection ID:CO001458
Collection Summary:Animals were sacrificed and the liver tissue was removed, snap frozen in liquid nitrogen and stored at -80°C until further analysis
Sample Type:Liver

Treatment:

Treatment ID:TR001478
Treatment Summary:All C57BL6J wildtype mice were bred locally and held under specific pathogen-free conditions at the Institute of Laboratory Animal Science at RWTH Aachen University Hospital. The day of birth was considered day 0, i.e. animals screened at day 1 were approximately 24 h old and verified to have ingested breast milk (abdominal milk spot). Mice were weaned at PND21.

Sample Preparation:

Sampleprep ID:SP001471
Sampleprep Summary:Solvents: Acetonitril (Merck KGaA, Darmstadt, Germany hypergrade for LC-MS) Water MiliQ, Extracting agent - ACN / H2O (1:1) Equipment 4 steel balls size M Eppendorf Tubes 2mL Tissue slicer (Rettberg, Germany) Centrifuge (Sigma) Work steps To approximately 100 mg of sample four steel balls of size M rae added in Eppendorf tubes. Then add for each mg of sample 5 µL of extracting agent. Shake the samples for 10 minutes at 30 Hz in the tissue slicer and centrifuge for 2 minutes at 14000 rpm. The supernatant is used for targeted analytics as described in the kit manufactures manual. Kit measurement The analysis was performed using the validated Bile Acid Kit (Biocrates Life Sciences, Inssbruck, Austria) as described in Pham et al. 2017 [1]. Data processing is carried out with the provided quantitation method Kit (Biocrates Life Sciences AG, Innsbruck, Austria). 1 Pham HT, Arnhard K, Asad YJ, Deng L, Felder TK, St John-Williams L, et al. Inter-Laboratory Robustness of Next-Generation Bile Acid Study in Mice and Humans: International Ring Trial Involving 12 Laboratories. The Journal of Applied Laboratory Medicine 2019;1:129-42.
Sampleprep Protocol Filename:sven_haange_20200602_Sample_preparation.pdf

Combined analysis:

Analysis ID AN002318
Analysis type MS
Chromatography type Reversed phase
Chromatography system UPLC (Waters Acquity, Waters Corporation, Milford, USA)
Column none
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name ABI Sciex 5500 QTrap
Ion Mode POSITIVE
Units µM

Chromatography:

Chromatography ID:CH001704
Instrument Name:UPLC (Waters Acquity, Waters Corporation, Milford, USA)
Column Name:none
Chromatography Type:Reversed phase

MS:

MS ID:MS002161
Analysis ID:AN002318
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Analyst version 1.6 Software from SCIEX. For Validation METIDQ Software version Boron from Biocrates
Ion Mode:POSITIVE
Analysis Protocol File:sven_haange_20201002_055740_MS-parameters.pdf