Return to study ST001412 main page
MB Sample ID: SA115879
Local Sample ID: | MICH-01533 |
Subject ID: | SU001486 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU001486 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
MICH-01533 | SA115879 | FL014430 | Obese neuropathy | Group |
Collection:
Collection ID: | CO001481 |
Collection Summary: | Plasma was collected in purple EDTA tubes with 10 mL of buffy coat, inverted 10 times, incubated for 30-90 minutes at room temperature, and centrifuged at 3000 rpm for 10 minutes. The plasma supernatant was collected by aspirating plasma to approximately 5 mm above the buffy coat and plasma samples were stored in 0.5 mL aliquots at -80C prior to metabolomics analysis. |
Sample Type: | Blood (plasma) |
Treatment:
Treatment ID: | TR001501 |
Treatment Summary: | None |
Sample Preparation:
Sampleprep ID: | SP001494 |
Sampleprep Summary: | Samples were prepared using the automated MicroLab STAR® system from Hamilton Company. Several recovery standards were added prior to the first step in the extraction process for QC purposes. To remove protein, dissociate small molecules bound to protein or trapped in the precipitated protein matrix, and to recover chemically diverse metabolites, proteins were precipitated with methanol under vigorous shaking for 2 min (Glen Mills GenoGrinder 2000) followed by centrifugation. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVap® (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis. |
Combined analysis:
Analysis ID | AN002362 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Waters Acquity |
Column | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE |
Units | peak area |
Chromatography:
Chromatography ID: | CH001732 |
Chromatography Summary: | Low pH polar |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH C18 (100 x 2mm,1.7um) |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS002204 |
Analysis ID: | AN002362 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Proprietary analytical software for integration and peak picking |
Ion Mode: | POSITIVE |