Return to study ST001427 main page

MB Sample ID: SA120159

Local Sample ID:B5
Subject ID:SU001501
Subject Type:Mammal
Subject Species:Sus scrofa
Taxonomy ID:9823

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001501
Subject Type:Mammal
Subject Species:Sus scrofa
Taxonomy ID:9823

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
B5SA120159FL014871infantPaediatric Group

Collection:

Collection ID:CO001496
Collection Summary:Samples were obtained from mechanically ventilated newborn piglets or group A (<5 days, n =12), infant piglets or group B (2 weeks, n =12) and child piglets or group C (4 weeks, n =12) of Topig F-1 Large White x Landrace breed. Whole blood samples were collected in K2-EDTA tubes, and they were immediately centrifuged at 950 g for 10 min at room temperature in order to obtain plasma. The supernatant was transferred to a cryovial and stored at -80 °C until analysis.
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR001516
Treatment Summary:Whole blood collected in K2-EDTA tubes were immediately centrifuged at 950 g for 10 min at room temperature in order to obtain plasma. The supernatant was transferred to a cryovial and stored at -80 °C until analysis.
Treatment Protocol Filename:OihaneAlboniga001_20200716_005253_PR_SP_SP.pdf

Sample Preparation:

Sampleprep ID:SP001509
Sampleprep Summary:SP.pdf was included with all the details related to sample preparation.
Sampleprep Protocol Filename:OihaneAlboniga001_20200716_005253_PR_SP_SP.pdf

Combined analysis:

Analysis ID AN002385 AN002386
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1200 Agilent 1200
Column Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um) Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6530 QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak Area Peak Area

Chromatography:

Chromatography ID:CH001752
Instrument Name:Agilent 1200
Column Name:Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH001753
Instrument Name:Agilent 1200
Column Name:Agilent Zorbax SB-C18 (100 x 2.1mm,3.5um)
Chromatography Type:Reversed phase

MS:

MS ID:MS002227
Analysis ID:AN002385
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:LC-MS.pdf with all the details related to the analysis of plasma samples is uploaded. Then, XCMS was used to process data by using the Isotopologue Parameters Optimization (IPO) package following the criteria reported by Albóniga et al. (Alboniga OE, Gonzalez O, Alonso RM, Xu Y, Goodacre R. Optimization of XCMS parameters for LC-MS metabolomics: An assessment of automated versus manual tuning and its effect on the final results. Metabolomics. 2020;16(1):14-020-1636-9) Finally, Plasma data matrix was processed with Matlab using the toolbox freely available online at https://github.com/Biospec/cluster-toolbox-v2.0. Intensity drop was corrected with the QC correction function included in the toolbox and then autoscaling was applied. Then multivariate and univariate analysis were carried out.
Ion Mode:POSITIVE
  
MS ID:MS002228
Analysis ID:AN002386
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:LC-MS.pdf with all the details related to the analysis of plasma samples is uploaded. Then, XCMS was used to process data by using the Isotopologue Parameters Optimization (IPO) package following the criteria reported by Albóniga et al. (Alboniga OE, Gonzalez O, Alonso RM, Xu Y, Goodacre R. Optimization of XCMS parameters for LC-MS metabolomics: An assessment of automated versus manual tuning and its effect on the final results. Metabolomics. 2020;16(1):14-020-1636-9) Finally, Plasma data matrix was processed with Matlab using the toolbox freely available online at https://github.com/Biospec/cluster-toolbox-v2.0. Intensity drop was corrected with the QC correction function included in the toolbox and then logarithm scaling was applied. Then multivariate and univariate analysis were carried out.
Ion Mode:NEGATIVE