MB Sample ID: SA122353

Local Sample ID:D5-control2
Subject ID:SU001515
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001515
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
D5-control2SA122353FL014970ControlSample Source
D5-control2SA122353FL014970Day5Treatment Duration
D5-control2SA122353FL014970ControlSample Source
D5-control2SA122353FL014970Day5Treatment Duration

Collection:

Collection ID:CO001510
Collection Summary:7 control fibroblasts samples and 7 patient-derived fibroblasts samples were collected at day 0 and day 5. Intracellular metabolites were extracted from cells cultured in 6 well plate while acyl-CoA and 5-methyltetrahydrofolate were extracted from cells cultured in 60 mm dish. Intracellular metabolites and acyl-CoA from cells were harvested as described previously using 80% methanol/water as solvent (PMID: 24410464, PMID: 24894601, PMID: 25795660) and dry pellets were stored in -80 °C freezer until ready for LC-MS analysis. For acyl-CoA and 5-methyltetrahydrofolate analysis, dry pellets were reconstituted into 30 μL of sample solvent (water containing 50 mM ammonium acetate), and 10 μL was injected into the LC-MS. For non-acyl-CoA polar metabolite analysis, pellets were reconstituted into 30 μL of sample solvent (water:methanol:acetonitrile, 2:1:1, v/v), and 3 μL was injected into the LC-MS.
Sample Type:Cultured fibroblasts

Treatment:

Treatment ID:TR001530
Treatment Summary:Patient-derived fibroblasts cultured in standard culture conditions (proliferative condition) and cells cultured for 5 days in low-serum conditions (non-proliferative condition). Patients carry disease-causing mutations in SUCLA2. Controls are fibroblasts from age-matched patients with other mitochondrial diseases.

Sample Preparation:

Sampleprep ID:SP001523
Sampleprep Summary:Intracellular metabolites and acyl-CoA from cells were harvested as described previously using 80% methanol/water as solvent (PMID: 24410464, PMID: 24894601, PMID: 25795660) and dry pellets were stored in -80 °C freezer until ready for LC-MS analysis. For acyl-CoA and 5-methyltetrahydrofolate analysis, dry pellets were reconstituted into 30 μL of sample solvent (water containing 50 mM ammonium acetate), and 10 μL was injected into the LC-MS. For non-acyl-CoA polar metabolite analysis, pellets were reconstituted into 30 μL of sample solvent (water:methanol:acetonitrile, 2:1:1, v/v), and 3 μL was injected into the LC-MS.

Combined analysis:

Analysis ID AN002407 AN002408 AN002409
Analysis type MS MS MS
Chromatography type HILIC HILIC Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters Xbridge amide (100 x 2.1mm,3.5um) Waters Xbridge amide (100 x 2.1mm,3.5um) Phenomenex Luna C18 (100 x 2.0mm,3um)
MS Type ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Exactive Plus Orbitrap Thermo Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE
Units peak area peak area peak area

Chromatography:

Chromatography ID:CH001769
Chromatography Summary:HILIC method is for general metabolomics analysis.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters Xbridge amide (100 x 2.1mm,3.5um)
Chromatography Type:HILIC
  
Chromatography ID:CH001770
Chromatography Summary:RPLC is for acyl-CoA and folate analysis.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Phenomenex Luna C18 (100 x 2.0mm,3um)
Chromatography Type:Reversed phase

MS:

MS ID:MS002248
Analysis ID:AN002407
Instrument Name:Thermo Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:POSITIVE
  
MS ID:MS002249
Analysis ID:AN002408
Instrument Name:Thermo Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:NEGATIVE
  
MS ID:MS002250
Analysis ID:AN002409
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:POSITIVE