Return to study ST001639 main page

MB Sample ID: SA150605

Local Sample ID:NJHC-01455
Subject ID:SU001716
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001716
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
NJHC-01455SA150605FL017687caseCOPD

Collection:

Collection ID:CO001709
Collection Summary:The Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) (ClinicalTrials.gov Identifier: NCT01969344) includes 2,771 subjects, aged 40-80 years with at least 20 pack-years of smoking. An additional 202 subjects were never smokers. Fasting blood drawn at the enrollment visit using a p100 tube. The first 649 subjects who returned for a 5-7 year visit (Visit 5) were selected for this study. The blood profiled were from the year 1 visit.
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR001729
Treatment Summary:The Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) (ClinicalTrials.gov Identifier: NCT01969344) includes 2,771 subjects, aged 40-80 years with at least 20 pack-years of smoking. An additional 202 subjects were never smokers. Fasting blood drawn at the enrollment visit using a p100 tube. The first 649 subjects who returned for a 5-7 year visit (Visit 5) were selected for this study. The blood profiled were from the year 1 visit.

Sample Preparation:

Sampleprep ID:SP001722
Sampleprep Summary:Following receipt, samples were inventoried and immediately stored at -80oC. Each sample received was accessioned into the Metabolon LIMS system and was assigned by the LIMS a unique identifier that was associated with the original source identifier only. This identifier was used to track all sample handling, tasks, results, etc. The samples (and all derived aliquots) were tracked by the LIMS system. All portions of any sample were automatically assigned their own unique identifiers by the LIMS when a new task was created; the relationship of these samples was also tracked. All samples were maintained at -80oC until processed. Samples were prepared using the automated MicroLab STARĀ® system from Hamilton Company. Several recovery standards were added prior to the first step in the extraction process for QC purposes. To remove protein, dissociate small molecules bound to protein or trapped in the precipitated protein matrix, and to recover chemically diverse metabolites, proteins were precipitated with methanol under vigorous shaking for 2 min (Glen Mills GenoGrinder 2000) followed by centrifugation. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVapĀ® (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis.

Combined analysis:

Analysis ID AN002681 AN002682 AN002683 AN002684
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo LTQ Thermo LTQ Thermo LTQ Thermo LTQ
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units AU AU AU AU

Chromatography:

Chromatography ID:CH001975
Chromatography Summary:Low pH polar
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH001976
Chromatography Summary:Low pH Lipophilic
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH001977
Chromatography Summary:High pH
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH001978
Chromatography Summary:HILIC
Instrument Name:Waters Acquity
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Chromatography Type:HILIC

MS:

MS ID:MS002480
Analysis ID:AN002681
Instrument Name:Thermo LTQ
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:POSITIVE
  
MS ID:MS002481
Analysis ID:AN002682
Instrument Name:Thermo LTQ
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:POSITIVE
  
MS ID:MS002482
Analysis ID:AN002683
Instrument Name:Thermo LTQ
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:NEGATIVE
  
MS ID:MS002483
Analysis ID:AN002684
Instrument Name:Thermo LTQ
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:NEGATIVE
  logo