Return to study ST001640 main page

MB Sample ID: SA151188

Local Sample ID:2P_002
Subject ID:SU001717
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001717
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
2P_002SA151188FL017690ControlTreatment

Collection:

Collection ID:CO001710
Collection Summary:Samples of both plasma and liver were collected from healthy patients and patients with chronic liver diseases.
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR001730
Treatment Summary:Healthy patients (control) versus CLD and HCC for plasma.

Sample Preparation:

Sampleprep ID:SP001723
Sampleprep Summary:Extraction of plasma lipids is based on the “Maytash'' method [1] which was subsequently modified. Extraction is carried out using a bi-phasic solvent system of cold methanol, methyl tert-butyl ether (MTBE), and water. In more detail, cold methanol (225 µL) containing a mixture of odd chain and deuterated lipid internal standards [lysoPE(17:1), lysoPC(17:0), PC(12:0/13:0), PE(17:0/17:0), PG(17:0/17:0), sphingosine (d17:1), d7-cholesterol, SM(17:0), C17 ceramide, d3-palmitic acid, MG(17:0/0:0/0:0), DG(18:1/2:0/0:0), DG(12:0/12:0/0:0), and d5-TG(17:0/17:1/17:0)] is added to a 20 µL sample aliquot, which is placed into a 1.5 mL Eppendorf tube, and the tube is vortexed for 10 s. Then, 750 µL of cold MTBE containing CE(22:1) (internal standard) are added, followed by vortexing for 10 s. and shaking for 6 min. at 4ºC. Phase separation is induced by adding 188 µL of mass spec-grade water. After vortexing for 20 s. The sample is centrifuged at 14,000 rpm for 2 min. The upper organic phase is collected in two 300 µL aliquots. One is stored at -20ºC as a backup and the other is evaporated to dryness in a SpeedVac. Dried extracts are resuspended using a mixture of methanol/toluene (9:1, v/v) (60 µL) containing an internal standard [12-​[[(cyclohexylamino)carbonyl]amino]-​dodecanoic acid (CUDA)] used as a quality control.

Combined analysis:

Analysis ID AN002685
Analysis type MS
Chromatography type Reversed phase
Chromatography system Agilent
Column Waters ACQUITY UPLC CSH C18
MS Type EI
MS instrument type QTOF
MS instrument name Agilent 6530 QTOF
Ion Mode POSITIVE
Units counts per second

Chromatography:

Chromatography ID:CH001979
Chromatography Summary:The LC/QTOFMS analyses are performed using an Agilent 1290 Infinity LC system (G4220A binary pump, G4226A autosampler, and G1316C Column Thermostat) coupled to either an Agilent 6530 (positive ion mode) or an Agilent 6550 mass spectrometer equipped with an ion funnel (iFunnel) (negative ion mode). Lipids are separated on an Acquity UPLC CSH C18 column (100 x 2.1 mm; 1.7 µm) maintained at 65°C at a flow-rate of 0.6 mL/min. Solvent pre-heating (Agilent G1316) was used. The mobile phases consist of 60:40 acetonitrile:water with 10 mM ammonium formate and 0.1% formic acid (A) and 90:10 propan-2-ol:acetonitrile with 10 mM ammonium formate and 0.1% formic acid. The gradient is as follows: 0 min 85% (A); 0–2 min 70% (A); 2–2.5 min 52% (A); 2.5–11 min 18% (A); 11–11.5 min 1% (A); 11.5–12 min 1% (A); 12–12.1 min 85% (A); 12.1–15 min 85% (A). A sample volume of 3 µL is used for the injection. Sample temperature is maintained at 4°C in the autosampler.
Instrument Name:Agilent
Column Name:Waters ACQUITY UPLC CSH C18
Column Temperature:65
Flow Gradient:0 min 85% (A); 0-2 min 70% (A); 2-2.5 min 52% (A); 2.5-11 min 18% (A); 11-11.5 min 1% (A); 11.5-12 min 1% (A); 12-12.1 min 85% (A); 12.1-15 min 85% (A).
Flow Rate:0.6 mL/min
Solvent A:60% acetonitrile/40% water; 0.1% formic acid; 10 mM ammonium formate
Solvent B:90% isopropanol/10% acetonitrile; 0.1% formic acid; 10 mM ammonium formate
Chromatography Type:Reversed phase

MS:

MS ID:MS002484
Analysis ID:AN002685
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:EI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction. Samples are injected (1.7 μl in positive mode and 5 μl in negative ion mode) with a needle wash for 20 seconds (wash solvent is isopropanol). The valve is switched back and forth during the run for washing; this has been shown to be essential for reducing carryover of less polar lipids.
Ion Mode:POSITIVE
  logo